Water chemistry is key to brewing the best beer possible, and that's where a pH meter becomes an essential tool
Measure your strike water's pH and make informed brewing salt additions to provide the ideal environment for enzymatic activity during the mash
Digital display is easy-to-read and provides instant test results—no need to do a color comparison like with pH strips
Automatic Temperature Compensation adjusts the results based on the temperature of the sample so you don't need to cool the sample before taking a reading
Electrode is protected by a waterproof cap so your storage solution won't evaporate and dry out the electrode
The KegLand pH Meter will get you a very accurate reading with its 0.01 pH resolution. The calibration process couldn't be easier to perform, just place the probe in the buffer solution closest to pH of the sample you'll be testing and press the button! This pH meter also includes ATC (Automatic Temperature Compensation) so you don't have to get your sample all the way down to room temperature before you take your reading.
3-point calibration allows this unit to be calibrated at three different standard levels - 4.00, 6.86 or 9.18. These standards are included with the pH meter, and refill packs are also available.
The pH meter features a replaceable probe in case yours is lost or damaged. Homebrewing can be a tough environment for your pH probe so we feel you shouldn't have to buy a whole new pH meter everytime your probe breaks. The cap that holds the probe storage solution has a very tight seal and should prevent your probe from drying out while not in use. Don't worry about getting this meter wet either, because the entire unit is waterproof!
Features:
Replaceable probe
ATC (Automatic Temperature Compensation)
Waterproof electrode cap
Accurate to 0.01 pH
Easy 3 point calibration
LR44/AG13 batteries included
Kegland Part Number: KL04169
NOTE: Upon first time use prior to calibration, rehydration of the electrode with MT624B is essential to get an accurate reading for correct calibration.
If you’re a serious homebrewer, you know the importance of proper pH during the brewing process. Use these calibration solutions to keep your pH meter reading accurately before each brew.
Includes 4oz each of 4.00 and 7.00 buffers. We package these solutions from bulk quantities to get you the best pricing. For testing, pour buffers into a small glass. You do not want to stick the probe of the pH meter into the buffer jars directly because you will eventually sacrifice the accuracy of your buffers.
Expires after 6 months if unopened. Expires after 3 months if opened.
Click here for a PDF of the MoreManual on proper pH Meter care.
This plastic syringe is perfect for measuring out acid additions or other small amounts of liquid. Perfectly suitable for multiple uses in brewing and winemaking applications.
Calibrated up to 10 ml. 1 ml is equal to 1 cc.
NOTE: The center nozzle syringe is not compatible with the Anton Paar EasyDens. You will need a syringe with offset nozzle.
Keep your KegLand pH Meter's probe in great condition by storing it in this storage solution. Letting your probe dry is the leading cause of degradation. By leaving your pH meter in this solution when not in use, you will extend the life of your probe and maintain more accurate readings.
KegLand Part Number: KL04183
For long term health of your elctrode use pH storage solution. It is a mixture of Potassium Chloride, Postassium Hydrogen Phthalate, Silver Nitrate, and Sodium Hydroxide.
Volume: 230 ml
Click here for a PDF of the MoreBeer Manual on proper PH Meter care.
Use buffer solutions to keep your pH meter calibrated. These are the same 3 solution powders that are included with the KegLand pen-style pH meter (MT624). We would strongly recommend if you haven't used your pH meter in a while to always use a buffer solution before you start your brew.
Directions:
Completely empty the powder into a clean glass jar
Add 8.5 oz of deinoized water
Stir until the powder has completely dissolved
KegLand Part Number: KL06279
Get an extremely accurate reading with this rugged bench-top pH meter. It offers the highest accuracy meter, with ATC, featuring a separate temperature probe for temperature readings independent of the electrode. The separate temperature probe allows you to check the temperature before submersing the electrode. Even though the name says "Bench-Top" it can easily be handheld. Temperature reading is in Celsius.
For long term health of your electrode, use our highly recommended pH storage solution MT618.
Features include:
Automatic Temperature Compensation up to 50 C (122 F)
0.01 accuracy with a 0-14 pH range
Push button calibration
2 year instrument warranty from Milwaukee
6 month electrode warranty
500 hour run-time on the battery
Click here for a PDF of the MoreBeer Manual on proper pH Meter care.
Electrode storage solution is designed specifically for maintaining pH meter electrodes in optimal condition. Before storage, add a small amount of storage solution to the cup/cover of the pH meter (enough to submerge the glass electrode). This will maintain hydration of the electrode, increasing its life and its ability to be calibrated.
One of the great features of the KegLand pH Meter is the replaceable probe. The probes of pH meters wear out through normal use. Instead of making you buy a whole new pH meter you can just get the probe!
Kegland Part Number: KL04176
A simple, low cost pH meter eliminates the guesswork of using pH strips.
Simple 1-point calibration, accuracy to 0.1 pH units, and a pH 0-14 range make this tester incredibly easy to live with. No more guessing at your mash pH!
Includes calibration screwdriver, batteries and user manual.
Milwaukee Part Number: pH600AQ
A replacement electrode for the MT608 & MT609 pH meter. The electrode is the consumable portion of the pH meter which actually makes the measurement. All pH electrodes wear out over time and must be replaced. If your meter is having trouble calibrating or the reading drifts then a bad electrode is the likely culprit.
Click here for a PDF of the MoreBeer Manual on proper PH Meter care.
Milwaukee Part Number: SE220
pH56 is a pocket pH meter with a lot of features. It has a resolution of 0.01 pH, a range of -2.00 to 16.00 pH, and an accuracy of 0.05 pH. It also reads temperature from 23.0 degrees F to 140 degrees F (-5.0-60 C), and has automatic temperature compensation. The unit is completely waterproof.
The pH56 has a stability indicator and hold function that freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through the operations. Calibration is made automatically in 1 or 2 points with memorized standard and NIST buffer sets. Auto power off saves battery power after non-use. The double-junction electrode can be replaced in a very fast and simple way! The modular design allows easy electrode and battery replacement.
Milwaukee Part Number: pH56
pH indicator strips in the range of 1-14 pH. Use these wide range strips for general determination of the pH, or to reduce the range before using a narrow range pH testing strip. Sold in a bag of 50 strips, with a color reference chart on the front of the bag.
pH indicator strips in the range of 1-14 pH. Use these wide range strips for general determination of the pH, or to reduce the range before using a narrow range pH testing strip. A color reference chart is located inside the booklet. 80 test strips per booklet.
7.00 can also be used for storage when pH storage solution is not available.
Expires after 6 months if unopened. Expires after 3 months if opened.
Click here for a PDF of the MoreBeer Manual on proper PH Meter care.
pH indicator strips in the range of 2.8 - 4.4 pH, the ranges typically seen in winemaking. The vial contains 100 strips, and a color reference chart for determining the pH on the outside of the vial.
A handy addition to any Home Lab, this wash bottle is great for cleaning out pipettes after use, rinsing pH electrodes and cleaning out components of your Aeration/Oxidation set. Also fun to squirt people with!
HI70300L is an electrode storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. Properly storing your pH electrode in a solution keeps the glass membrane well hydrated which maintains proper function and provides accurate readings.
Special formulation to minimize bacterial growth on your electrode.
Clearly marked expiration date and lot number for traceability.
Designed for storing any pH or ORP electrode.
HI70300L is a specially formulated electrode storage solution that can be used to store your pH electrode*. To ensure the best response time, the sensor tip and the reference junction of the pH electrode should be kept moist when not in use. Placing the pH electrode in a small glass filled with storage solution or replacing the solution in the protective cap is an easy way to store the electrode. The HI70300L should also be used to rehydrate the electrode after cleaning by soaking for at least one hour before taking measurements.
Air tight bottle with a tamper-proof seal
Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
Hanna pH storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
HI7007L is a premium quality pH 7.01 buffer solution.
With lot number and expiration date clearly marked on the label and an air tight, tamper-proof seal to ensure the quality of the solution, Hanna’s line of pH calibration solutions are an easy way to get great pH measurements every time.
Air tight bottle with tamper-proof seal for quality.
Color coded label for easy identification of ph 7 buffer value.
Perfect for routine maintenance to ensure accurate readings while extending the life of the electrode.
Our pH Technical Buffer Solutions are dedicated to measurements that require extremely accurate pH monitoring, and come with a certificate of analysis prepared by comparison against NIST standards. Our pH Technical Buffer Solutions are dedicated to measurements that require extremely accurate pH monitoring, and come with a certificate of analysis prepared by comparison against NIST standards.
Air tight bottle with tamper-proof seal
Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
Color coded label for easy pH buffer value identification
Easy to identify different buffer values
HI7004L is a premium quality pH 4.01 buffer solution.
With lot number and expiration date clearly marked on the label and an air tight, tamper-proof seal to ensure the quality of the solution, Hanna’s line of pH calibration solutions are an easy way to get great pH measurements every time.
Air tight bottle with tamper-proof seal for quality.
Color coded label for easy identification of pH buffer values.
Perfect for routine maintenance to ensure accurate readings while extending the life of the electrode.
Our pH Technical Buffer Solutions are dedicated to measurements that require extremely accurate pH monitoring, and come with a certificate of analysis prepared by comparison against NIST standards. Our pH Technical Buffer Solutions are dedicated to measurements that require extremely accurate pH monitoring, and come with a certificate of analysis prepared by comparison against NIST standards.
Air tight bottle with tamper-proof seal
Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
Hanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
Color coded label for easy pH buffer value identification
Easy to identify different buffer values
Designed to bring simplicity to pH testing during the wine making process, the HI981033 Wine pH Tester is engineered to solve the challenge of measuring the samples with a high solids content. The built-in probe features a glass body, spherical tip, and Hanna's Clogging Prevention System (CPS) that resists clogging 20x longer than a standard ceramic frit, making it ideal for measuring the pH during the wine making process.
Specialized electrode for spot checking of juice, must, and wine during the wine making process.
Comes with all the necessary solutions and batteries- everything you need to get started measuring right away.
±0.2 pH accuracy
Better Features for Better Testing
An onscreen stability indicator ensures the highest level of confidence in your results. The selectable auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.
Pocket Sized
The compact size makes the Wine pH Tester ideal for on-the-go testing. A large LCD display provides at-a-glance readings from any angle and single button operation streamlines the testing process for any user.
Long Battery Life
The included CR2032 Li-ion battery provides up to 1000 hours of continuous use. The battery icon will blink to let you know it is time to change the battery so you never miss a measurement.
CPS™ Sleeve Junction
Clogging Prevention System (CPS) technology was designed for pH measurements in samples that have a high solids content. When the electrode become dirty, the PTFE sleeve can be moved to clean the ground glass surface, rejuvenating the junction for a 20x longer electrode lifespan.
Spherical Glass Tip
The spherical shaped tip design allows for a wider area of contact with the sample for a faster measurement.
Glass Body
A glass body is easy to clean, is chemically resistant, and quick to reach thermal equilibrium for a faster, more stable measurement.
Cleaning Solution for Wine Deposits and Stains
Your Wine pH Tester comes with cleaning solution that has been engineered to keep our electrode free from wine juice stains and must deposits. This concentrated combination of detergents cleans your meter quickly and effectively so that your meter stays in optimum condition.
pH 3 & 7 Buffer Sachets
When performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate.
Storage Solution
Proper storage of your electrode will ensure reliable measurements and a long electrode life. Our storage solution is specially formulated to keep the pH glass hydrated while minimizing organic growth.
Simple pH readings with +/- 0.2 pH accuracy
Comes with everything you need to get started right away
Batteries included (appx 1000hrs of battery life)
Compact size perfect for on the go testing with a large LCD display for at a glance readings
Clogging Prevention System (CPS) allows for measurement of samples with high solids content
The Milwaukee MW151 MAX 3-in-1 PRO pH/ORP/Temp Bench Logging Meter is preferred by people testing all types of samples viscus or not, in a variety of applications that cause other pH meters and electrodes to fail. The logging feature allows log-on-demand and log-on-stability features that ensure all readings are accurate and not entered incorrectly. The MA917B/1 Milwaukee double junction electode is refillable and easy to clean. From brewers and wine makers to hydroponic growers, labs and water treatment, the MW151 MAX is your Bench Logging Meter for fast, accurate readings.
Accuracy
People choose the MW151 MAX 3-in-1 PRO pH/ORP/Temp Portable Logging Meter to improve the accuracy of their testing program. With up to 5 point calibration and 7 standard buffer choices (2 custom buffers also), the meter can be quickly calibrated to a higher accuracy compared with one or two point calibration. The MW151 MAX meter is accurate to ± 0.002 pH. 8 x more accurate than some alternative meters.
The meter comes with a refillable, glass, double junction pH electrode and MA831R temperature sensor allowing the meter to automatically adjust the pH reading for the effect of temperature (ATC).
The meter can also be used as a very accurate thermometer with accuracy +/-0.4°C (+/-0.8°F).
Low Maitenance
The MW151 MAX pH/OPR/Temp Bench Logging Meter comes with the Milwaukee glass, double junction MA917B/1 pH electrode. This is Milwaukee's top selling lab grade electrode for a reason. Designed to be both low maintenance (refillable) and able to withstand more challenging samples (double junction). The MA917B/1 is ideal for use in beer making, winemaking, hydroponics, laboratories and many other applications.
Features:
Fast easy-to-read results with large duel level digital LCD readout.
Extreme accuracy to ±0.002 pH | +/- 1 mV OPR | +/- 0.4°C (+/-0.8°F).
Extended pH range (-2.00 pH to 20.00 pH / -2.000 to 20.000 pH).
Lightweight, sleek design with small benchtop footprint.
Simple easy-to-use logging and USB download functions, manual or on stability up to 1,000 logs.
Electrode diagnostics feature checks and displays the condition of the pH electrode.
Easy measurement: just place the electode and temperature probe in the sample, gently stir and wait for the reading to stabilize.
Simple push button, automatic up to 5 point calibration for increased accuracy.
Up to 7 Standard calibration solutions (1.68, 4.01, 6.86,7.01, 9.18, 10.01 and 12.45) and 2 custom choices.
Refillable, glass, double junction lab grade pH electrode for low maintenance and high performance with a screw on cap to ensure proper storage.
Built-in rechargeable battery with 8 hours battery life (battery included).
Selectable Auto-off feature.
Alphanumeric LCD display messages for friendly, intuitive information, warnings and error messages.
Internal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).
3 feet probe cables for extra flexibility when testing.
Care and Use
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing Bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference Junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning and Maitenance
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution. Also:
Inspect the electotrode for damage or scratches, if present replace the electrode.
Inspect the cable. The connection cable and insulation must be intact.
Connectors should be clean and dry.
Rinse off salt deposits with water or DI water.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus pH meter accurate. Also, calibrate after cleaning or a long period of storage.
Specifications:
pH Range: -2.00 to 20.00 pH / -2.000 to 20.000 pH
ORP Range: ±2000.0 mV
Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
Resolution: 0.01 pH / .001 pH
Resolution: 0.1mV
Resolution: 0.1°C / 0.1°F)
Accuracy: ±0.01 pH / ±0.002 pH @ 25°C / 77°F
Accuracy: ±1mV
Accuracy: ±0.4°C |±0.8°F
pH Calibration: up to 5 point automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers
Temperature Compensation: Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual
pH electrode: MA917B/1 glass, double junction pH electrode (supplied)
Temperature probe: MA831R (included)
Logging: Maximum 1,000 samples (stored in up to 100 lots) / on demand, 200 samples on stability, 200 samples/ Interval logging, 1000 logs
PC Connectivity: 1 USB Port, 1 micro USB port
Power supply: 12VDC, 5 VDC USB Adapter (included)
Battery life: Approx. 8 hours of use
Auto-off: Selectable 5, 10, 30, 60 min. or off
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
Weight: 0.9 kg / 2.0 lbs.
The tool is utilized for electrode removal on select Hanna testers. With a simple twist of the removal tool, the tester electrode can safely and easily be removed and replaced with a new one. pH and conductivity (EC) electrodes naturally fatigue over time, requiring replacement to ensure measurements are obtained quickly and accurately.
HI7061L is a general purpose cleaning solution for use with pH and ORP electrode that can be used for a variety of applications. pH electrodes become dirty with use and can produce inaccurate results. Use our General Purpose pH Electrode Cleaning Solution to prolong the life of your electrode and ensure accurate readings.
Specially formulated for cleaning pH and ORP electrodes
Clearly marked expiration date and lot number for traceability.
Air-tight seal to ensure the quality of the solution
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.
Air tight bottle with tamper-proof seal
Ensures quality and freshness of solution
Each bottle marked with lot number and expiration date.
Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
HI5003 is a premium quality pH 3.00 technical calibration buffer that is NIST traceable and supplied with a Certificate of Analysis. Hanna calibration buffers have the lot number and expiration date clearly marked on the label and are air tight with a tamper-proof seal to ensure the quality of the solution. Hanna's line of technical calibration buffers have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.
Supplied with Certificate of Analysis
Accuracy of +/- 0.01 pH @ 25°C
Temperature chart of the actual pH value at various temperatures printed on each bottle
HI5003 is a premium quality pH 3.00 technical calibration buffer produced in accordance with ISO 3696/BS3978 standards, using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to +/- 0.01 pH @ 25°C and are traceable to NIST Standard Reference Materials (SRM).
The HI5003 is supplied with certificate of Analysis
Product code
Lot number
Mean lot value
SRM’s that were used
Manufacturing date
Expiration date
Color coded label for easy pH buffer value identification
Easy to identify different buffer values
Solution does not contain any dyes that may stain the reference cell of a pH electrode.
Premium quality pH 3.00 technical calibration buffer that is NIST traceable and supplied with a COA
Accuracy of +/- 0.01 pH @ 25C
Temperature chart of the actual pH value at various temperatures printed on each bottle
Solution does not contain any dyes that may stain the reference cell of a pH electrode
Replacement pH electrode for the SC-300 Analyzers that have a manufacturing date after February 2016. Includes the pH Electrode Storage solution. The pH electrode should be properly stored in its electrode storage solution. With proper care and storage, this electrode will have a 2-3 year lifespan beginning with first use.
Vinmetrica Troubleshooting Guide
Double Junction, refillable glass electrode with BNC connector and 1m cable. Replacement for the electrode that is included with the Milwaukee MW151 MAX pH/ORP/Temp Logging Bench Meter. The electrode is the consumable portion of the pH meter which actually makes the measurement. All pH electrodes wear out over time and must be replaced. If your meter is having trouble calibrating or the reading drifts then a bad electrode is the likely culprit.
Milwaukee Part Number: MA917B/1
.30M KCl (potassium chloride) solution for refillable pH/ORP electrodes. Fresh electrolyte solution ensures accurate calibration and measurement with your pH meter. For best results, electrolyte should be replenished or completely replaced every 3-6 months.
To Use:
Wearing Gloves, Drain existing electrolyte solution from the electrode by shaking upside down over the sink. You may need to use the tip of a small pipette or a syringe to break the surface tension of the liquid. Using the same pipette or syringe, replace the solution you just drained with a fresh lot from the bottle.
Store capped and refrigerated and out of the reach of children.
edge® digital wine pH meter kit delivers precision while offering simplicity and versatility in a sleek design.
Upgrade to the Hanna edge® wine pH kit for professional winemakers. The HI2020W allows you to add a conductivity probe and a dissolved oxygen probe to give you full versatility. Fast results, ultra-accurate, hassle-free analysis.
Complete meter kit for measuring pH in wine.
CAL Check™ feature ensures the accuracy of the meter.
Great for professional and home winemakers.
The Importance of pH in Wine Making
The pH of wine is important to determine because it will affect the quality of the final product in terms of taste, color, oxidation, chemical stability and other factors. Generally in winemaking, the higher the pH reading, the lower amount of acidity in the wine. Three important factors in determining the pH of wine include the ratio of malic acid to tartaric acid, the amount of potassium, and the total amount of acid present.
The edge HI2020W wine pH meter kit includes all the necessary supplies to determine the pH of wine must and juice accurately. The meter supplied with the HI2020W is the multiparameter edge, HI2020. The HI2020 is an advanced meter that is rich in features including using digital electrodes that can be swapped out anytime to switch to a different parameter, built in rechargeable battery, two USB ports, datalogging, automatic calibration, GLP (good laboratory practice) data for last calibrations, and Hanna’s exclusive calibration check feature that will alert the user to potential problems during calibration including when to clean the electrode and when the buffer might be contaminated. The HI2020 is a versatile pH meter for winemaking that be used as a benchtop, portable and even a wall mount to conserve space. The HI2020 is one of the most advanced meters available but the most important aspect in measuring pH is having the correct sensor for the application.
The HI2020W wine kit is packaged with the HI10480 (MT620Z) in place of the normally supplied HI11310. The HI10480 is a specially designed pH electrode that is resistant to clogging to the solids found in grape juice and must. This double junction, refillable pH electrode has a unique ground glass junction and PTFE sleeve to provide unsurpassed performance for the wine industry. A standard pH electrode will have a ceramic junction that can be easily clogged by solids. When this happens the pH readings will be erratic and drift over time before stabilizing on the actual pH value of the wine sample. The HI10480 with CPS technology will prevent the junction from clogging. The HI10480 is a digital electrode that when used with the edge HI2020 will change the default buffer set from pH 4.01and 7.01 to pH 3.00 and 7.01.
The edge HI2020W (MT620) wine pH meter (kit) includes the HI180-1 compact magnetic mini-stirrer. The use of a magnetic stirrer allows for proper mixing and the sample to be homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time of a sensor in achieving a stable reading.
The edge HI2020W wine pH kit also includes all the solutions for calibration and maintenance. In order to ensure the highest of accuracy in measurement it is important to bracket the calibration buffers around the expected reading. Since the pH of wine is less than pH 4.01 it is important to calibrate at a lower pH value. For calibration the kit includes the HI5003 (MT611) pH 3.00 and the HI5007 pH 7.01 technical calibration buffer. Each bottle of buffer NIST traceable is supplied with a certificate of analysis that includes lot number, expiration date and reference materials used in production.
For maintenance the The HI70635L cleaning solution for wine deposits and the HI70300L (MT631)electrode storage solution. When the “clean electrode” message is displayed during the calibration of the HI2020 edge or there is a poor probe condition (i.e. less than 30%) then soak the HI10480 in the cleaning solution for 15 minutes to clean any deposits from the glass surface. After cleaning the probe should be rinsed with purified water and then allowed to soak in the storage solution for 2-3 hours. The electrode storage solution is also used when the electrode is not in use. Either place a small amount into the storage cap or into a beaker in order to maintain a properly hydrated electrode.
Importance of maintaining a clean pH electrode
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for its designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged.
Benchtop
Portable, or Wall Mount versatile pH meter
Swappable digital electrodes
Built in rechargeable battery
Two USB ports
Automatic calibration,and data logging for GLP data
Large easy to read display
NOTE: The shape of the stir plate may differ from what is shown in the example photo. The function and approximate size will be the same, but it may be round or square depending on what the supplier has in stock.
The HI10480 is a digital pH electrode with built-in temperature sensor. This application specific electrode is designed for measuring pH in wine and must. Measuring the pH of wine is a critical step to ensure the quality of a final product. This electrode features a built-in microchip that stores sensor type, serial number, and calibration information. It also features a double junction reference, Clogging Prevention System (CPS) technology, glass body, and spherical tip.
Spherical Glass Tip
Clogging Prevention System
3.5 mm connector designed exclusively to be used with Hanna Instruments edge® Tablet Meters.
Built-In Microchip
The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot-swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built-in temperature sensor and while working in a humid environment.
Spherical Glass Tip
The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability. The HI10480 utilizes a low temperature (LT) glass formulation that has a resistance of around 50 megaohms at 25°C. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI10480 is suitable to use with samples that measure from 0 to 80°C.
CPS Sleeve Junction
CPS™ (Clogging Prevention System) is an innovation in electrode technology. Conventional pH electrodes use ceramic junctions that clog quickly when used in wine. When the junction is clogged, the electrode does not function. CPS™ technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows proper flow of the liquid, while the PTFE sleeve repels dirt. As a result, pH electrodes with CPS™ stay fresh up to 20 times longer than conventional electrodes.
Double Junction Reference
A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.
Glass Electrode Body
The glass electrode body is suitable for a wide range of applications due to its chemical resistance. The glass electrode is compatible with many non-aqueous solvents and other aggressive chemicals. Glass is also resistant to many forms of radiation, such as ultraviolet radiation.
Built in temperature sensor
Application specific electrode for measuring pH in wine and must
Built in microchip that stores sensor type, serial number, and calibration information
Features a double junction reference with Clogging Prevention System (CPS) technology, a glass body, and a spHerical tip
Probe features a 3.5mm connector designed exclusively to be used with Hanna Instruments edge Tablet Meters
The HI1048B is a glass body, refillable, sleeve junction pH electrode with a BNC connector. This electrode features a double junction reference, Hanna's Clogging Prevention System (CPS) technology and spherical glass sensing bulb made with general purpose glass. This pH electrode is ideal for wine must and juice due to their high solids content that would clog a standard general purpose pH electrode.
Clogging Prevention System (CPS™) Technology
Refillable Electrode
Double Junction Design
Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.
The HI1048B uses general purpose (GP) glass, spherical bulb, glass body, sleeve junction with CPS™ technology, double junction and is refillable with 3.5M KCl, making it ideal for wine must, juice, and other samples with a high solids content.
General Purpose Glass Formulation
General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25°C and is suited for measuring the pH of samples that are at ambient temperatures. The HI1048B is suitable to use with samples that measure from 0 to 80°C.
Spherical Glass Tip
The spherical shaped tip design allows for a wide area of contact with the measured sample. This permits a faster electrode response with a higher degree of stability.
CPS Sleeve Junction
Clogging Prevention System (CPS) technology is an innovation in for the improvement of pH measurements in samples that have a high solids content. Conventional pH electrodes use ceramic junctions that can clog quickly when used in samples that have a high solids content such as wine must or juice. When the junction is clogged, the electrode does not function. CPS technology utilizes the porousness of ground glass coupled with a PTFE sleeve to prevent clogging of the junction. The ground glass allows the proper flow of the liquid, while the PTFE sleeve repels solids. As a result, pH electrodes with CPS technology take up to 20 times longer to be fouled as compared to conventional electrodes.
Double Junction Reference
A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contain sulfides that can cause the silver to precipitates and clog the junction. The clogging of the junction will result in drifty and erratic readings.
Refillable
The HI1048B is a refillable probe. Since it is a double junction pH electrode, the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode fill solutions.
Glass Electrode Body
The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature
dependent. The faster the equilibrium the steadier the reference potential.
BNC Connector
The HI1048B has a BNC connector. This type of connector is universal in that it can be used on any pH meter that has a female BNC probe input. Other types of connectors include DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.
Single Junction Versus Double Junction pH Electrodes
Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.
Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.
Able to measure samples 0-80C
Glass body, refillable sleeve junction
pH electrode with a BNC connector and a 0.5m cable
Clogging Prevention System (CPS) Technology
Refillable Electrode
Double Junction Design
The HI700635P is a highly effective cleaning solution that is specially formulated for use with pH electrodes that become coated with wine juice and must deposits. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction. Each sachet has the lot number and expiration date stamped on it and is made of light block foil ensuring freshness each time one is opened. Hanna's line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened sachet.
Specially formulated cleaning solution to remove wine deposits from a pH electrode
Convenient, one-time use sachets ensure freshness of solution
The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.
The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI700635P is a cleaning solution made specifically for the wine industry, where electrodes can become coated with wine particulates and deposits found in juice and must.and must.
Light block foil packaging
• Light-tight packet helps to prevent against degradation by UV light
One-time use sachet packets
• Ensures quality and freshness of solution
Each sachet marked with lot number and expiration date
• Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.
Specially formulated cleaning solution to remove wine deposits from a pH electrode
Convenient one-time use sachets ensure freshness of solution
Light-tight packet helps to prevent against degradation by UV light