Detecting your location...

Milwaukee MC122 PRO pH Controller

    Description

    Accurate. Simple. Reliable. 24/7 pH Control.
    The Milwaukee MC122 PRO pH controller lets you measure and adjust pH levels automatically.

    The MC122 controller automatically monitors and fine-tunes the pH levels. Just set your pH parameters and let the MC122 do the rest. The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.

    The MC122 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.

    Features

    Accuracy
    The Milwaukee PRO pH controller offers an accuracy to ±0.2 pH with two point manual calibration.

    Automation
    The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.

    Compatible dosing pump
    Milwaukee offers the MP810 dosing pump

    Easy installation
    The pH Controller comes with a complete mounting kit including a probe holder.

    Design features

    • Fast easy to read current results with large digital LCD readout
    • Accurate to ±0.2 pH
    • Simple two-point calibration for increased accuracy with manual trimmers for easy adjustment
    • 5.5 to 9.5 pH alarm set point range is easily accessible on the front panel
    • Alarm activated when reading is above or below set point
    • Comes with full mounting kit including probe holders
    • Lab grade, double junction, gel filled probe designed for low maintenance
    • 6.5’ probe cables for extra flexibility
    • 12 VDC power supply
    • Small footprint of 5.9 x 3.2 x 1.35”
    • Lightweight monitor at approx 6.3 oz.

    Use and Care 
    pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

    Sensing bulb
    The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

    Reference junction
    The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

    You can extend the life of your pH electrode in the following ways.

    Storage
    The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

    Store the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

    This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

    Cleaning
    Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

    Calibration
    The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.

     

    Milwaukee MC122 PRO pH Controller

      Product form

      SKU: MT8125

      $208.15

      Shipping
      Free Shipping
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Lead and lead compounds, which is/are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

        Description

        Accurate. Simple. Reliable. 24/7 pH Control.
        The Milwaukee MC122 PRO pH controller lets you measure and adjust pH levels automatically.

        The MC122 controller automatically monitors and fine-tunes the pH levels. Just set your pH parameters and let the MC122 do the rest. The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.

        The MC122 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.

        Features

        Accuracy
        The Milwaukee PRO pH controller offers an accuracy to ±0.2 pH with two point manual calibration.

        Automation
        The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.

        Compatible dosing pump
        Milwaukee offers the MP810 dosing pump

        Easy installation
        The pH Controller comes with a complete mounting kit including a probe holder.

        Design features

        • Fast easy to read current results with large digital LCD readout
        • Accurate to ±0.2 pH
        • Simple two-point calibration for increased accuracy with manual trimmers for easy adjustment
        • 5.5 to 9.5 pH alarm set point range is easily accessible on the front panel
        • Alarm activated when reading is above or below set point
        • Comes with full mounting kit including probe holders
        • Lab grade, double junction, gel filled probe designed for low maintenance
        • 6.5’ probe cables for extra flexibility
        • 12 VDC power supply
        • Small footprint of 5.9 x 3.2 x 1.35”
        • Lightweight monitor at approx 6.3 oz.

        Use and Care 
        pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

        Sensing bulb
        The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

        Reference junction
        The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

        You can extend the life of your pH electrode in the following ways.

        Storage
        The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

        Store the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

        This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

        Cleaning
        Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

        Calibration
        The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.

         

        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.

        Login

        Forgot your password?

        Don't have an account yet?
        Create account