Milwaukee MC811US MAX pH/EC/Temp Monitor

    Description

    Accurate. Simple. Reliable. 24/7 pH/EC/Temp Monitoring.
    Why Guard when you can Monitor! The Milwaukee MC811 MAX pH/EC/Temp Monitor lets you monitor your pH/EC/Temp levels 24/7 automatically.

    Summary
    The MC811 MAX Monitor automatically monitors and displays pH/EC/Temp levels.  Just calibrate the parameters and let the Milwaukee MAX Monitor do the rest.

    The Milwaukee MC811 MAX pH/EC/Temp Monitor is preferred by people looking to know 24/7 what their pH and nutrient levels are on an ongoing basis. Common uses are nutrient tanks, Hydroponics and aquariums.

    The Milwaukee MAX pH/EC/Temp Monitor offers:

    Accuracy
    The Milwaukee MAX Monitor offers an accuracy to ± 0.2 pH with two point manual calibration, EC accuracy of ±2% Full Scale and ±0.5 °F (0.3 °C) temperature accuracy.

    Automation
    Just calibrate the parameters and begin to monitor 24/7!

    Easy installation
    The MC811 MAX pH/EC/Temp Monitor comes with with two complete probe mounting kits.

    Design features

    • Fast, easy-to-read current results with 3 large digital backlit LCD readouts.
    • Simple two-point pH calibration and one-point EC, for increased accuracy with manual trimmers for easy adjustment
    • Gel-filled, double junction, lab grade pH electrode for low maintenance and high performance
    • Low maintenance fixed EC probe
    • 6.5’ probe cables for extra flexibility when testing
    • 12 VDC power supply
    • Mount above the sample to be tested or rest on a flat surface next to the sample
    • Compact size of only 6.3” x 4.3” x 1.4”
    • Weighs only 1.2 lbs
    • Range:0.0 - 12.0 pH | 0.00 to 5.00 mS/cm | 14.0°F to 140.0°F
    • Resolution:0.1 pH | 0.01 mS/cm | 0.1°F / 0.1°C
    • Accuracy:± 0.2 ph | ± 2% Full Scale | ±0.5°F (±0.3°C)
    • Calibration:pH Manual, 2 Point (trimmer) | EC, Manual 1 point | Temp. Factory Calibrated

    Use and Care 
    pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

    Sensing bulb
    The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

    Reference junction
    The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

    You can extend the life of your pH electrode in the following ways.

    Storage
    The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

    Store the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

    This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

    Cleaning
    Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

    Calibration
    The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.

     

    Milwaukee MC811US MAX pH/EC/Temp Monitor

      Product form

      SKU: MT8124

      $308.20

      Shipping
      Free Shipping
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Lead, which is/are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

        Description

        Accurate. Simple. Reliable. 24/7 pH/EC/Temp Monitoring.
        Why Guard when you can Monitor! The Milwaukee MC811 MAX pH/EC/Temp Monitor lets you monitor your pH/EC/Temp levels 24/7 automatically.

        Summary
        The MC811 MAX Monitor automatically monitors and displays pH/EC/Temp levels.  Just calibrate the parameters and let the Milwaukee MAX Monitor do the rest.

        The Milwaukee MC811 MAX pH/EC/Temp Monitor is preferred by people looking to know 24/7 what their pH and nutrient levels are on an ongoing basis. Common uses are nutrient tanks, Hydroponics and aquariums.

        The Milwaukee MAX pH/EC/Temp Monitor offers:

        Accuracy
        The Milwaukee MAX Monitor offers an accuracy to ± 0.2 pH with two point manual calibration, EC accuracy of ±2% Full Scale and ±0.5 °F (0.3 °C) temperature accuracy.

        Automation
        Just calibrate the parameters and begin to monitor 24/7!

        Easy installation
        The MC811 MAX pH/EC/Temp Monitor comes with with two complete probe mounting kits.

        Design features

        • Fast, easy-to-read current results with 3 large digital backlit LCD readouts.
        • Simple two-point pH calibration and one-point EC, for increased accuracy with manual trimmers for easy adjustment
        • Gel-filled, double junction, lab grade pH electrode for low maintenance and high performance
        • Low maintenance fixed EC probe
        • 6.5’ probe cables for extra flexibility when testing
        • 12 VDC power supply
        • Mount above the sample to be tested or rest on a flat surface next to the sample
        • Compact size of only 6.3” x 4.3” x 1.4”
        • Weighs only 1.2 lbs
        • Range:0.0 - 12.0 pH | 0.00 to 5.00 mS/cm | 14.0°F to 140.0°F
        • Resolution:0.1 pH | 0.01 mS/cm | 0.1°F / 0.1°C
        • Accuracy:± 0.2 ph | ± 2% Full Scale | ±0.5°F (±0.3°C)
        • Calibration:pH Manual, 2 Point (trimmer) | EC, Manual 1 point | Temp. Factory Calibrated

        Use and Care 
        pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

        Sensing bulb
        The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

        Reference junction
        The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.

        You can extend the life of your pH electrode in the following ways.

        Storage
        The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

        Store the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.

        This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

        Cleaning
        Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.

        Calibration
        The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.

         

        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.

        Login

        Forgot your password?

        Don't have an account yet?
        Create account