    The Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

    The Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.

    Design Features

    • Fast, easy-to-read results with large digital LCD readout.
    • Galvanic probe means no conditioning time.
    • Repeatable, accuracy to ±1.5% of reading.
    • Water Proof IP67 Rated.
    • Lightweight and portable.
    • Simple 1 or 2 % saturation calibration points at 100% (water saturated air) and 0% (zero oxygen solution). 
    • Dedicated GLP key to store and recall data on system status.
    • Available log space for up to 1000 records.
    • Logged data export via USB cable.
    • Altitude and Salinity compensation. 
    • Automatic temperature compensation °F & °C.
    • Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
    • 2 O-rings MA861, membranes and one protective cap included.
    • Electrolyte MA9072S 30 mL
    • 10 feet probe cable for extra flexibility when testing.
    • 3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.
    • Range:0.0 to 45.00 mg/L (ppm) O2 | % Saturation O2 0.0 to 300.0% | Temp. -20.0 to 120.0°C / -4.0 to 248.0°F
    • Resolution:O2 0.01 mg/L (ppm) | % Saturation O2 0.1% | Temperature 0.1°C / 0.1°F
    • Accuracy:O2 ±1.5% of reading ±1 digit| Temperature ±0.4°C (±0.8°F)
    • Calibration:One or Two % Saturation calibration points 0% (MA9070) and 100% (water saturated air)

    Care and Maintenance

    Probe Maintenance:
    The silver cathode should always be bright and untarnished.  If it is tarnished or stained, the cathode should be cleaned gently witha lint-free cloth.

    • Rinse the probe with deionized or distilled water.
    • Replace the membrane cap using fresh electrolyte. 
    • Recalibrate meter.

    Membrane Maintenance:    

    • For accurate and stable measurements, perfect condition of the membrane surface is needed.  Protect the thin membrane from scratches, abrasion or contact with solids.
    • If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
    • If fouled, rinse it carefully with distilled or deionized water.  If damaged, replace the membrane cap.

    Note:  Change the membrane every 8 weeks or more frequently if used in a specially fouling environment.  Check and replace the electrolyte fill solution every 4 weeks.

    Storage: 

    After taking measurements, switch the meter off and clean the probe before storage.  When not in use the probe should be stored with the plastic cap on.

    For short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.

    For long term storage, the probe should be stored dry:

    1. Disconnet the probe from the meter.

    2. Unscrew the membrane cap.

    3. Remove any electrolyte solution from the cap.

    4. Rinse the probe anode/cathode assembly with distilleed water and blot dry.

    5. Screw the membrane cap onto the probe until the membrane cap is hand tight.

     

    Milwaukee MW605 MAX Waterproof Galvanic Dissolved Oxygen Meter With Automatic Calibration

      Product form

      SKU: MT8105

      $833.75

      Shipping
      Free Shipping
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Lead, which is/are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

        Description

        The Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

        The Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.

        Design Features

        • Fast, easy-to-read results with large digital LCD readout.
        • Galvanic probe means no conditioning time.
        • Repeatable, accuracy to ±1.5% of reading.
        • Water Proof IP67 Rated.
        • Lightweight and portable.
        • Simple 1 or 2 % saturation calibration points at 100% (water saturated air) and 0% (zero oxygen solution). 
        • Dedicated GLP key to store and recall data on system status.
        • Available log space for up to 1000 records.
        • Logged data export via USB cable.
        • Altitude and Salinity compensation. 
        • Automatic temperature compensation °F & °C.
        • Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
        • 2 O-rings MA861, membranes and one protective cap included.
        • Electrolyte MA9072S 30 mL
        • 10 feet probe cable for extra flexibility when testing.
        • 3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.
        • Range:0.0 to 45.00 mg/L (ppm) O2 | % Saturation O2 0.0 to 300.0% | Temp. -20.0 to 120.0°C / -4.0 to 248.0°F
        • Resolution:O2 0.01 mg/L (ppm) | % Saturation O2 0.1% | Temperature 0.1°C / 0.1°F
        • Accuracy:O2 ±1.5% of reading ±1 digit| Temperature ±0.4°C (±0.8°F)
        • Calibration:One or Two % Saturation calibration points 0% (MA9070) and 100% (water saturated air)

        Care and Maintenance

        Probe Maintenance:
        The silver cathode should always be bright and untarnished.  If it is tarnished or stained, the cathode should be cleaned gently witha lint-free cloth.

        • Rinse the probe with deionized or distilled water.
        • Replace the membrane cap using fresh electrolyte. 
        • Recalibrate meter.

        Membrane Maintenance:    

        • For accurate and stable measurements, perfect condition of the membrane surface is needed.  Protect the thin membrane from scratches, abrasion or contact with solids.
        • If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
        • If fouled, rinse it carefully with distilled or deionized water.  If damaged, replace the membrane cap.

        Note:  Change the membrane every 8 weeks or more frequently if used in a specially fouling environment.  Check and replace the electrolyte fill solution every 4 weeks.

        Storage: 

        After taking measurements, switch the meter off and clean the probe before storage.  When not in use the probe should be stored with the plastic cap on.

        For short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.

        For long term storage, the probe should be stored dry:

        1. Disconnet the probe from the meter.

        2. Unscrew the membrane cap.

        3. Remove any electrolyte solution from the cap.

        4. Rinse the probe anode/cathode assembly with distilleed water and blot dry.

        5. Screw the membrane cap onto the probe until the membrane cap is hand tight.

         

        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.

        Login

        Forgot your password?

        Don't have an account yet?
        Create account