Detecting your location...

Milwaukee MW190 MAX Dissolved Oxygen Bench Meter With Automatic Calibration With Logging

    Description

    The Milwaukee MW190 MAX Bench Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

    The Milwaukee MW190 MAX DO Bench Meter is preferred by people looking for lab level accuracy without the high cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, education, water treatement plants and laboratories.

    Design features

    • Fast, easy-to-read results with large digital LCD readout.
    • Repeatable, accuracy to ±1.5% FS.
    • Lightweight and has a small benchtop footprint.
    • Single offset or dual point slope with open air 100% saturation calibration. 
    • Altitude and Salinity compensation. 
    • Automatic temperature compensation.
    • Uses MA845 (included) reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
    • 5 o-rings, membranes and one protective cap included
    • 2 meter probe cable for extra flexibility when testing
    • Logging up to 50 samples.
    • 12 VDC power supply.
    • Easy RS232/USB opto-isolated
    • Complete with DO probe, initial calibration solutions and cables.
    • MA841 Replacement Membranes.  
    • D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:
    • Range:0.00 to 45.00 mg/L (ppm) O2 | 0.0 to 300.0 % O2| Temp. -5.0 to 55.0°C / 23.0 to 131.0°F
    • Resolution:O2 0.01 mg/L (ppm) | 0.1% O2 | Temperature 0.1°C / 0.1°F
    • Accuracy:O2 ±1.5% of Full Scale| Temperature ±0.4°C (±0.8°F)
    • Calibration:Automatic, single (offset) or dual with slope 100% saturated air

    Care and Use

    Probe Preparation Calibration Procedure  
    D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:

    1. Remove the the red and black cap. This cap is used for protection during shipping. 

    2. Wet the sensor by soaking the bottom 2.5 cm of the probe in electrolyte (MA9071) for 5 minutes.

    3. Rinse the membrane (supplied with meter) with electrolyte solution while shaking it gently. Refill with clean electrolyte solution.

    4. Gently tap the sides of the membrane with the fingertip to ensure that no air bubbles remain trapped. To avoid damaging the membrane, do not tap the membrane directly on the bottom.

    5.  Place the O-Ring (suppield with membranes) properly inside the membrane cap.

    6. With the sensor facing down, screw the cap clockwise. Some electrolyte solution will overflow. 

    7. Turn the unit on use on/off key.

    8. All LCD tags are displayed and a beep is heard while the instrument performs a test.

    9. The "COND" message will be displayed for about 45 seconds to inform the user that the probe is in auto-conditioning mode (automatic polarization).

    10. Once "COND" dissappears, the probe is polarized and the instrument can be calibrated.

    Calibration Offset Procedure

    1. Remove the clear protective cap.

    2. Submerge the probe in MA9070 zero oxygen solution and stir for about 2-3 minutes.

    3. Press CAL. The "WAIT" tag will blink on the LCD until reading is stable.

    4. When the reading is stable, "READY" & "ACCEPT" tags are blinking.  Press ACCEPT to confirm the "0.0%" D.O. calibration.

    NOTE:  When the instrument is not in use, place the CLEAR plastic cap (supplied with probe) over the membrane.

    Extra tips

    • Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
    • Always use fresh electrolyte solution (MA9071).
    • Always use MA841 membranes ONLY.
     

    Milwaukee MW190 MAX Dissolved Oxygen Bench Meter With Automatic Calibration With Logging

      Product form

      SKU: MT8112

      $1,094.80

      Shipping
      Free Shipping
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Lead and lead compounds, which is/are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

        Description

        The Milwaukee MW190 MAX Bench Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.

        The Milwaukee MW190 MAX DO Bench Meter is preferred by people looking for lab level accuracy without the high cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, education, water treatement plants and laboratories.

        Design features

        • Fast, easy-to-read results with large digital LCD readout.
        • Repeatable, accuracy to ±1.5% FS.
        • Lightweight and has a small benchtop footprint.
        • Single offset or dual point slope with open air 100% saturation calibration. 
        • Altitude and Salinity compensation. 
        • Automatic temperature compensation.
        • Uses MA845 (included) reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
        • 5 o-rings, membranes and one protective cap included
        • 2 meter probe cable for extra flexibility when testing
        • Logging up to 50 samples.
        • 12 VDC power supply.
        • Easy RS232/USB opto-isolated
        • Complete with DO probe, initial calibration solutions and cables.
        • MA841 Replacement Membranes.  
        • D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:
        • Range:0.00 to 45.00 mg/L (ppm) O2 | 0.0 to 300.0 % O2| Temp. -5.0 to 55.0°C / 23.0 to 131.0°F
        • Resolution:O2 0.01 mg/L (ppm) | 0.1% O2 | Temperature 0.1°C / 0.1°F
        • Accuracy:O2 ±1.5% of Full Scale| Temperature ±0.4°C (±0.8°F)
        • Calibration:Automatic, single (offset) or dual with slope 100% saturated air

        Care and Use

        Probe Preparation Calibration Procedure  
        D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:

        1. Remove the the red and black cap. This cap is used for protection during shipping. 

        2. Wet the sensor by soaking the bottom 2.5 cm of the probe in electrolyte (MA9071) for 5 minutes.

        3. Rinse the membrane (supplied with meter) with electrolyte solution while shaking it gently. Refill with clean electrolyte solution.

        4. Gently tap the sides of the membrane with the fingertip to ensure that no air bubbles remain trapped. To avoid damaging the membrane, do not tap the membrane directly on the bottom.

        5.  Place the O-Ring (suppield with membranes) properly inside the membrane cap.

        6. With the sensor facing down, screw the cap clockwise. Some electrolyte solution will overflow. 

        7. Turn the unit on use on/off key.

        8. All LCD tags are displayed and a beep is heard while the instrument performs a test.

        9. The "COND" message will be displayed for about 45 seconds to inform the user that the probe is in auto-conditioning mode (automatic polarization).

        10. Once "COND" dissappears, the probe is polarized and the instrument can be calibrated.

        Calibration Offset Procedure

        1. Remove the clear protective cap.

        2. Submerge the probe in MA9070 zero oxygen solution and stir for about 2-3 minutes.

        3. Press CAL. The "WAIT" tag will blink on the LCD until reading is stable.

        4. When the reading is stable, "READY" & "ACCEPT" tags are blinking.  Press ACCEPT to confirm the "0.0%" D.O. calibration.

        NOTE:  When the instrument is not in use, place the CLEAR plastic cap (supplied with probe) over the membrane.

        Extra tips

        • Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
        • Always use fresh electrolyte solution (MA9071).
        • Always use MA841 membranes ONLY.
         
        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.

        Login

        Forgot your password?

        Don't have an account yet?
        Create account