Milwaukee MI455US Mini Titrator for Sulfur Dioxide in Wine

    Description

    Lab Grade. Accurate. Simple. Automated.
    The Milwaukee MI455US PRO SO₂ Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The MI455US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode. Using a modified Ripper method, this mini-titrator does not rely on color change but uses potentiometric detection. The MI455US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI455US uses a preprogrammed method and specialized ORP electrode combined with an algorithm to determine the end of the titration reaction.

    Summary
    The Milwaukee MI455 PRO SO2 Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.

    The Milwaukee PRO SO2  PRO Mini-Titrator offers:

    • Accuracy
      The MI455 PRO Mini-Titrator is accurate to 5% of the reading with a resolution of 1 ppm with a range of 0-400 ppm. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode.
       
    • Simplicity
      The MI455 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.
       
    • Automated operation
      The MI455 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI455 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.

    Design Features

    • Measure both free and total SO₂
    • Easy measurement: just measure the wine sample, add the reagents as directed, prepare ORP probe and pump, add the stabilizer and start titration by pressing the start button.
    • Refillable, double junction lab grade ORP electrode.
    • 700 rpm built-in stirrer.
    • Simple and reliable peristaltic pump that ensure high dosing repeatability.
    • Compact 8.2 x 8.4” footprint.
    • Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.
    • Replacement Reagent Kit:  Mi555-KIT.  Individual bottle here: Individual Reagent Bottles. 
    • Replacement ORP Electrode:  MA924B/1.

    Care and Use 
    ORP electrodes usually start performing poorly because of problems with the probe. The two parts of the ORP probe that cause problems are the glass sensing bulb and the reference junction.

    Sensing Bulb
    The glass bulb loses sensitivity with use and will eventually fail. This is true of all ORP probes.

    Reference Junction
    The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the ORP electrode will no longer function.

     

    You can extend the life of your ORP electrode in the following ways.

    Cleaning and Storage
    All ORP sensors have a limited life and response time gets longer with age. Properly maintaining your ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!

    Storage
    To minimize clogging the ORP probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

    Storing in ORP probe storage solution MA9015 will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.

    The best way to store the probe is with the probe's cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

    Cleaning an Maintenance
    Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also:

    1. Inspect the electrode for damage or scratches, if present replace the electrode.

    2. Inspect the cable.  The connection cable and insulation must be intact.

    3. Connectors should be clean and dry.

    4. Rinse off salt deposits with water or DI water.

     

    Milwaukee MI455US Mini Titrator for Sulfur Dioxide in Wine

      Product form

      SKU: MT8102

      $954.50

      Shipping
      Free Shipping
      Shipping
      Paid Shipping
      Drop Ship
      Drop Ship
      Discount Exclusion
      Discount Exclusion
      Freight
      Freight Only
      Pre-book
      Pre Order

        Prop 65 Warning WARNING : This product can expose you to chemicals including Lead, which is/are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.

        Description

        Lab Grade. Accurate. Simple. Automated.
        The Milwaukee MI455US PRO SO₂ Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The MI455US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode. Using a modified Ripper method, this mini-titrator does not rely on color change but uses potentiometric detection. The MI455US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI455US uses a preprogrammed method and specialized ORP electrode combined with an algorithm to determine the end of the titration reaction.

        Summary
        The Milwaukee MI455 PRO SO2 Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.

        The Milwaukee PRO SO2  PRO Mini-Titrator offers:

        • Accuracy
          The MI455 PRO Mini-Titrator is accurate to 5% of the reading with a resolution of 1 ppm with a range of 0-400 ppm. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode.
           
        • Simplicity
          The MI455 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.
           
        • Automated operation
          The MI455 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI455 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.

        Design Features

        • Measure both free and total SO₂
        • Easy measurement: just measure the wine sample, add the reagents as directed, prepare ORP probe and pump, add the stabilizer and start titration by pressing the start button.
        • Refillable, double junction lab grade ORP electrode.
        • 700 rpm built-in stirrer.
        • Simple and reliable peristaltic pump that ensure high dosing repeatability.
        • Compact 8.2 x 8.4” footprint.
        • Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.
        • Replacement Reagent Kit:  Mi555-KIT.  Individual bottle here: Individual Reagent Bottles. 
        • Replacement ORP Electrode:  MA924B/1.

        Care and Use 
        ORP electrodes usually start performing poorly because of problems with the probe. The two parts of the ORP probe that cause problems are the glass sensing bulb and the reference junction.

        Sensing Bulb
        The glass bulb loses sensitivity with use and will eventually fail. This is true of all ORP probes.

        Reference Junction
        The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the ORP electrode will no longer function.

         

        You can extend the life of your ORP electrode in the following ways.

        Cleaning and Storage
        All ORP sensors have a limited life and response time gets longer with age. Properly maintaining your ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!

        Storage
        To minimize clogging the ORP probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

        Storing in ORP probe storage solution MA9015 will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.

        The best way to store the probe is with the probe's cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

        Cleaning an Maintenance
        Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also:

        1. Inspect the electrode for damage or scratches, if present replace the electrode.

        2. Inspect the cable.  The connection cable and insulation must be intact.

        3. Connectors should be clean and dry.

        4. Rinse off salt deposits with water or DI water.

         
        Important Warnings & Shipping Info +
        Shipping Icon
        Free Shipping: Fast & Free Shipping over $79
        Shipping Icon
        Shipping Rates Apply: Bulk items like grain, bottles, and malt are excluded from our free shipping promotion due to their weight, and often dropship items. Standard shipping rates apply and are calculated at checkout based on your location and order size.
        Drop Ship Icon
        Drop Ship: This product will ship directly from the supplier. Delivery may take 1-4 weeks depending on the vendor.
        Discount Exclusion Icon
        Discount Exclusion: This item is not eligible for sitewide price reductions or percentage discounts. Learn more.
        Freight Icon
        Freight Shipping: This item ships freight only.
        Pre-book Icon
        Pre Order: This item is available for Pre-Order. Full payment is required to reserve stock.

        Login

        Forgot your password?

        Don't have an account yet?
        Create account