Detecting your location...
$150 OFF your KOMOS build Orders $1,200+ · Code KOMOS150 · Ends in 14 days
Shop the Event

pH Testing

Shop by collection
52 products

  • Milwaukee - M10010B pH 10.01 Calibration Solution Sachets (25)

    Milwaukee M10010B pH 10.01 Calibration Solution Sachets (25)

    Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month. M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.  Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. Design Features pH 10.01 Calibration Buffer Solution - 20 mL (box of 25) Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Color coded for easy identification  

    $34.50

  • Milwaukee - MI456US PRO Mini Titrator for Titratable Acidity in Wine Milwaukee - MI456US PRO Mini Titrator for Titratable Acidity in Wine

    Milwaukee MI456US PRO Mini Titrator for Titratable Acidity in Wine

    Lab Grade. Accurate. Simple. Automated. The Milwaukee MI456US PRO TA Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The instrument comes with a preprogrammed analysis method designed for Total Titratable Acidity measurements on wine. The MI456US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode. The MI456US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI456US uses a preprogrammed method and lab grade pH electrode combined with an algorithm to determine the end of the titration reaction. Summary The Milwaukee MI456 PRO TA Mini Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The Milwaukee PRO TA Mini Titrator offers: Accuracy The MI456 PRO Mini Titrator is accurate to 5% of the reading with a resolution of 0.1 g/L with a range of 0.0 to 25.0 g/L of tartaric acid. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode. Simplicity The MI456 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up. Automated Operation The MI456 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI456 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation. Design Features Easy measurement: just measure the wine sample, add the reagents as directed, prepare pH probe and pump, add the stabilizer and start the titration by pressing the start button. Refillable, double junction lab grade pH electrode. Automatic temperature compensation. Range: 0.0 to 25.0 g/L of tartaric acid Accuracy: 5% of reading Method: Acid-base titration 700 rpm built-in stirrer. Simple and reliable peristaltic pump that ensure high dosing repeatability. Compact 8.2 x 8.4” footprint. Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface. Replacement Kit:  Mi556-KIT.  Individual Reagent Bottles.   Replacement pH electrode:  MA919B/1. Care and Use  pH electrodes usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction. Sensing Bulb The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes. Reference Junction The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.   You can extend the life of your pH electrode in the following ways. Cleaning and Storage All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time!  This will be needed to help clean and condition the pH electrode before use! Storage To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged. Storing in pH probe storage solution MA9015 or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe. The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage. Cleaning an Maintenance Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also: Inspect the electrode for damage or scratches, if present replace the electrode. Inspect the cable.  The connection cable and insulation must be intact. Connectors should be clean and dry. Rinse off salt deposits with water or DI water. Calibration The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your MI456 Mini-Titrator readings accurate. Also, calibrate after cleaning or a long period of storage.  

    $954.50

  • Milwaukee - MI455US Mini Titrator for Sulfur Dioxide in Wine Milwaukee - MI455US Mini Titrator for Sulfur Dioxide in Wine

    Milwaukee MI455US Mini Titrator for Sulfur Dioxide in Wine

    Lab Grade. Accurate. Simple. Automated. The Milwaukee MI455US PRO SO₂ Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The MI455US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode. Using a modified Ripper method, this mini-titrator does not rely on color change but uses potentiometric detection. The MI455US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI455US uses a preprogrammed method and specialized ORP electrode combined with an algorithm to determine the end of the titration reaction. Summary The Milwaukee MI455 PRO SO2 Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The Milwaukee PRO SO2  PRO Mini-Titrator offers: Accuracy The MI455 PRO Mini-Titrator is accurate to 5% of the reading with a resolution of 1 ppm with a range of 0-400 ppm. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode.   Simplicity The MI455 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.   Automated operation The MI455 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI455 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation. Design Features Measure both free and total SO₂ Easy measurement: just measure the wine sample, add the reagents as directed, prepare ORP probe and pump, add the stabilizer and start titration by pressing the start button. Refillable, double junction lab grade ORP electrode. 700 rpm built-in stirrer. Simple and reliable peristaltic pump that ensure high dosing repeatability. Compact 8.2 x 8.4” footprint. Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface. Replacement Reagent Kit:  Mi555-KIT.  Individual bottle here: Individual Reagent Bottles.  Replacement ORP Electrode:  MA924B/1. Care and Use  ORP electrodes usually start performing poorly because of problems with the probe. The two parts of the ORP probe that cause problems are the glass sensing bulb and the reference junction. Sensing Bulb The glass bulb loses sensitivity with use and will eventually fail. This is true of all ORP probes. Reference Junction The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the ORP electrode will no longer function.   You can extend the life of your ORP electrode in the following ways. Cleaning and Storage All ORP sensors have a limited life and response time gets longer with age. Properly maintaining your ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use! Storage To minimize clogging the ORP probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged. Storing in ORP probe storage solution MA9015 will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe. The best way to store the probe is with the probe's cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage. Cleaning an Maintenance Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also: Inspect the electrode for damage or scratches, if present replace the electrode. Inspect the cable.  The connection cable and insulation must be intact. Connectors should be clean and dry. Rinse off salt deposits with water or DI water.  

    $954.50

  • Low stock! HALO Wireless Wine pH Meter HALO Wireless Wine pH Meter

    Hanna HALO® Wireless Wine pH Meter (Hanna# HI10482)

    Our HALO® for home and craft winemakers has a glass body, spherical tip, and Hanna's Clogging Prevention System (CPS) that resists clogging 20x longer. All readings are transmitted directly to your Apple or Android device or the edge®blu. Take laboratory grade pH and temperature measurements using your smart phone or tablet. Easily connect to the Hanna Lab App at the press of a button via Bluetooth® wireless technology. Group your data by time or notation. Email it for storage or share it with friends or colleagues. The HALO® Wireless Wine pH Meter incorporates Bluetooth® Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of wine.   General Purpose Glass Formulation General Purpose (GP) glass provides the best response over the entire pH range and can be used for a wide range of applications.   Built-In Temperature Sensor HI10482 features a built-in temperature sensor for temperature measurement and compensation.   Movable CPS Sleeve Junction Clogging Prevention System (CPS) technology was designed for pH measurements in wine juice and must samples that have a high solids content. CPS technology utilizes a ground glass junction that allows proper flow of the liquid with a PTFE sleeve that repels solids. When the HALO become dirty, the PTFE sleeve can be moved to clean the ground glass surface rejuvenating the junction resulting in a 20x longer electrode lifespan.   Real-Time Data Display of pH and temperature updated every second. Readings are automatically saved to a history file every hour, limited only by the available memory on the device.   Fluid, Dynamic Graphing Measurements can be displayed alone on the display, with tabulated data, or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.   GLP (Good Laboratory Practice) Displays date and time of current calibration, offset, and average slope, along with calibrated buffers, mV values, temperature and slopes between each buffer.   Calibration Reminder & Measurement Alarms The Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.   Log & Share Data Saved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.   Help & Tutorials Demo mode helps you explore features of the Hanna Lab App. General app information, HALO information, pH tutorial, maintenance tutorial, and contact information are available in help.   HALO® Features/Benefits Connects to Hanna Lab App with a compatible Apple or Android Device via Bluetooth Smart Technology (Bluetooth 4.0) Up to five-point pH calibration with seven standard pH buffers available   Calibration reminder • Alerts you when HALO needs calibration • Appropriate preprogrammed calibration buffer set for application specific Halo pH electrodes   Real-time data • Displays pH and temperature updated every second   Basic Good Laboratory Practice (GLP) • Displays date and time of current calibration along with offset and average slope   Full GLP • Displays date and time of current calibration, offset and average slope along with calibrated buffers, mV values, temperature and slopes between each buffer   Fluid, dynamic graphing • Measurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing   Measurement alarms • Alerts you if the measurement threshold is exceeded   One button sample tagging • Pressing either the icon in the Hanna Lab App or button on the HALO will tag sample data for easy reference   Data logging with custom annotations • Saved log files may be annotated with measurement specific information • Data is autosaved every hour   Four ways to save and share data: • All data since last autosave • Annotations only • All data within a timed interval • Annotations only within a timed interval • Share data via email in CSV format   Help and tutorials: • Demo mode to help explore features of the Hanna Lab App • General app information • General HALO information • pH tutorial • Maintenance tutorial • Contact information   Compatibility: HALO is compatible with the following devices:   Android Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.   iOS iPad (3rd generation or newer) iPhone (4S or newer) iPod Touch (5th generation or newer)   HI2202 edgeblu Meter   Take laboratory grade PH and temperature measurements using your smart phone or tablet Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology Group your data by time or notation Email it for storage or share it with friends or colleagues Hanna's Clogging Prevention System (CPS) resists clogging 20x longer, monitor data with real time graphing and display        

    $301.00

You have seen 52 out of 52 products

Login

Forgot your password?

Don't have an account yet?
Create account