How to Gain Maximum Control over Wort Chilling Operations
by A.J. deLange (Brewing Techniques)
Approaches to Measuring Counterflow Chiller Performance and Getting Predictable Results
Simple equations and graphs can help you accurately estimate chill times and water consumption in counterflow chiller operations. The adventurous can use slightly more advanced formulas to dial in the numbers with even greater accuracy.
One of the keys to successful fermentations and high-quality finished beer is to chill wort from boiling to the target fermentation temperature, quickly and reliably. To that end, brewers use a variety of techniques and equipment, from immersing the brew kettle in ice water to using a dedicated piece of equipment known as a wort chiller. Counterflow and immersion wort chillers are used extensively because they are more efficient and reliable than the low-tech method of immersing the entire brew kettle (see box for explanation of counterflow chiller design and operation).
This article does not address the debate over which of the two wort chillers is best. Rather, it shows how brewers can take advantage of the counterflow chiller design to gain greater control over the chilling process and get predictable results, even as the particular demands of your brewing methods change from batch to batch, beer style to beer style.
The formulas and graphs presented in this article will enable you to quantify the performance of counterflow wort chillers and set flow rates that produce the results you want. The key is the parameter Q, which is a measure of the cooling capacity of the chiller (expressed in units of flow rate [gallons per hour, for example]). Q has been referenced in a couple of published articles; this article explains it more fully.
The approach described here has direct application to any brewery using counterflow wort chillers. Among other things, it enables you to answer the following questions:
- If I have to chill my wort in a specified time frame, what flow rates should I use for the wort and coolant?
- If I have to chill my wort to a specific temperature, what efficiency do I require of the chiller to accomplish this goal?
- If I have to conserve water (coolant), what combination of wort and coolant flow rates will chill my wort within an acceptable time frame and consume the least water?
- What’s Q got to do with all this, and how do I determine the value of Q for my wort chiller?
In beginning our discussion, I assume that Q is a constant to simplify understanding of how a chiller works and how to predict its performance. Toward the end of the article, I present measurement data on three commercially available wort chillers that exhibit variation in Q as wort flow varies, and I extend the discussion to account for this. While this adds some complexity, brewers will still be able to answer all the questions posed at the beginning of the article.
| Anatomy of Counterflow Wort Chillers |
| Counterflow wort chillers consist of two channels placed in physical contact with one another so that heat is exchanged between them. Various configurations are possible, but the design most familiar to home brewers is 25 ft of copper refrigeration tubing (usually â in., but sometimes ½ in.) inserted into a larger diameter garden hose, with suitable fittings at either end. Hot wort flows through the smaller diameter tubing inside, and cold water flows through the garden hose surrounding the tube so that heat transfers from the wort tube to the water. The coaxial tubes are nearly always arranged into a moderate diameter coil to make the unit easier to handle and store. In another common arrangement, the wort channel is again small-diameter (usually â -in.) copper tubing, but wound into a small coil that is then inserted into a larger rigid PVC pipe, 4.5 in. or larger, through which the cooling water flows. Other designs are usually variations of these two and typically feature some means of enhancing the thermal contact between the two channels, such as fins attached to the inside tube, for example. In larger chillers for commercial brewing operations, the channels are often cut into stainless steel plates with the inlets and outlets arranged in such a way that multiple plates can be stacked, thus allowing a wide range of total channel lengths to be implemented. A chiller’s cooling capacity is directly proportional to the length of the channels. Doubling the length of a chiller of constant geometry thus doubles the amount of wort that can be chilled in a given time period. Regardless of the implementation, the wort flows through its channel in one direction and the coolant through its channel in the opposite direction. This means that the wort leaving the chiller contacts the coolant entering the system, where the coolant is coldest. For this reason, counterflow chillers ensure the greatest degree of cooling possible. |
Before delving into the question of how to determine the value of Q for our chillers, let’s first explore some applications of Q in our breweries. The examples in the following sections assume known values of Q.
Looking for a wort chiller? Click here to browse our selection of counterflow wort chillers!
Chiller Efficiency
A chiller’s effectiveness is defined in terms of efficiency, which would be 100% if the temperature of the wort leaving the chiller were exactly the same as the temperature of the coolant entering it (the 100% condition). It is impossible for the exiting wort to be cooler than the coolant, and for practical purposes 100% efficiency is unattainable, so efficiencies are generally somewhat less than 100% — how much less depends on the rates at which the hot wort and coolant flow past each other. The slower the wort flow, the faster the coolant flow, and the greater the thermal conductivity between wort and coolant, the greater the efficiency.
Determining the efficiency of any chiller setup is a simple matter. First, we must determine the potential temperature drop for wort flowing through the chiller, which is the difference between the temperature of the hot wort entering the system and the temperature of the coolant as it enters the system. The chiller’s efficiency is simply the fraction of this potential temperature drop that is actually realized. To calculate efficiency, take the difference between the entering and exiting wort temperatures (actual temperature drop) and divide that number by the potential temperature drop:
[1]
where η (the Greek letter eta) is efficiency, Tw(0) is the temperature of the wort at its point of entry to the wort chiller, and Tw(L) and Tc(L) are the temperatures of the wort and coolant at the outlet (L represents the length of the chiller).
Suppose you know the efficiency values for your chiller when operating at given wort and coolant flow rates. It is now a simple matter to compute the temperature at the outlet of your chiller. First, determine the equivalent efficiency loss (1 minus its efficiency, where the efficiency is expressed as a decimal); this is the chiller’s potential cooling loss. Multiply this potential cooling loss by the potential drop to get the actual cooling loss (in degrees). Add the cooling loss to the coolant inlet temperature to get the wort output temperature. This relationship can be expressed with the following equation:
Tw(L) = Tc(L) + (1 – η) [Tw(0) – Tc (L)] [2]
For example, if a chiller uses 55 °F (~12.75 °C) cooling water with wort entering at 212 °F (100 °C), the potential temperature drop is 212 – 55 = 157 °F (87 °C). If it is operating at 98% efficiency, the lost potential is (1 – 0.98) X 157 = 3.14 °F (~1.75 °C), and the outlet temperature is 55 + 3.14 = 58.14 °F (~14.5 °C).
Understanding chiller efficiency is the key to understanding how to predict and control the variables of wort flow rate, coolant flow rate and consumption, and chill time.
Interested in an immersion wort chiller? Click here to browse our selection!
Determining Chiller Efficiency Graphically
Chiller performance can be determined graphically, without the use of detailed calculations. Figure 1 displays curves of constant efficiency. The vertical axis (y-axis) is the flow rate of the wort, and the horizontal axis (x-axis) is the flow rate of the coolant. In both cases, the flow rates are normalized by Q; wort flow is further adjusted for specific gravity (ρ).
To use the graph, first multiply the wort flow rate by the wort’s specific gravity and divide by Q, and find that value on the vertical axis of Figure 1. Suppose, for example, your chiller has a Q of 68. If wort of specific gravity 1.050 flows through it at 34 gal/hour, the normalized flow is (34 X 1.050)/68 = 0.525. Thus, we look for the value 0.525 on the vertical axis.
Similarly, divide the coolant flow rate by Q and find that value on the horizontal axis. To continue the example, let’s assume our coolant flow rate is 240 gal/hour, which divided by 68 gives a normalized flow of 3.53. That’s the number we look for on the horizontal axis.
If we draw a horizontal line from 0.525 on the vertical axis and draw a vertical line from 3.53 on the horizontal axis, the lines intersect. The point of intersection reveals the efficiency of this particular chiller setup. These lines have been drawn in on Figure 1, and they intersect between 80% and 85%, but closer to 85%, from which we can estimate that the efficiency is about 83%. This compares well with the value of 82.8% obtained using formulas.
Each curve represents a constant efficiency. Any combination of normalized wort and coolant flows that falls on a particular curve will have the efficiency of that curve. For example, a normalized wort flow of 0.2 and a normalized coolant flow of 10 result in 99.326% efficiency, as does a normalized wort flow of 0.17 and a normalized coolant flow of 1.0. (Both of these points fall on the heavy curve of Figure 1.)
How to Use Efficiency Estimates
Using efficiency data to determine required flow rates: Brewers usually know how cold they want the output wort to be. With known hot wort and inlet coolant temperatures, you can quickly determine the efficiency you require to get there. Once you know the required efficiency, you can move along the curve for that efficiency and find nominalized flow rates for wort and coolant that meet your operating criteria. Understanding the relationships between efficiency and flow rates enables you to take dramatic strides in the control of wort chilling operations.
As an example, suppose you want to cool 212 °F wort to 52 °F (11 °C) using 50 °F (10 °C) cooling water. Assuming the wort enters the chiller at boiling, you need the following efficiency:
η = (212 – 52)/(212 – 50) = 0.9876, or 98.8%
Looking at the chart, the closest efficiency line is the 99% line, so you may choose any point along that line, such as a normalized wort flow of 0.14 and a normalized coolant flow of 0.3, or a normalized wort flow of a little over 0.2 and a normalized coolant flow of 10.
Comparing the two choices raises a couple of interesting observations about the graph. First, the first option results in a longer chilling time but a lower coolant flow rate; the second operating point gives a faster chilling time but requires a higher water flow rate. If you want quick chilling to minimize DMS formation in your beer, you would probably be inclined to select the second option. Second, we can see that all the curves roll over and become pretty flat at a normalized coolant flow rate of about 1. You can run the chiller at this value (a big difference from 10) and still have a normalized wort flow rate of 0.18 (a relatively little difference from 0.2).
The graph gives us a range of normalized values for wort and coolant flow rates, but how do we know the actual flow rates to use? Determining actual flow rates is a simple matter of working the calculations backwards and un-normalizing them.
Small chillers of the type usually purchased by home brewers generally have Qs around 65. Using that value with the three choices just offered, we can un-normalize (multiply the normalized flow by Q) and arrive at some real numbers (Table I). The times and coolant consumption values shown in Table I are based on a 10-gal batch (we chose this batch size because a chiller with a Q of 65 is really too small for larger batches).
To simplify the calculation, we can ignore the specific gravity factor in the wort flow rate. Neglecting this factor causes the calculated un-normalized wort flow rate to be bigger (by about 5% for S.G. 1.050) than it would be if specific gravity were taken into account, resulting in poorer chiller efficiency than calculated. Although this effect can usually be ignored, you should be aware of it and may wish to use the specific gravity factor in all calculations (or perhaps only those applied to dense worts).
The table shows that the slowest option is the most economical in terms of the amount of coolant water used, which is what one might suspect. The fastest option will cool the wort in two-thirds the time, but at a cost of 25 times the cooling water and a coolant flow rate that is not achievable with most home water supplies. The intermediate option requires about 2.5 times the cooling water of the slow option and reduces cooling time by 15 minutes. This middle ground seems the best choice, but in special circumstances as where, for example, DMS production is a big problem or water conservation is an important issue, brewers might prefer one of the other choices. This example demonstrates the value of these curves and formulas.
The rule of thumb: Note that the intermediate choice here also reveals an easy-to-remember rule of thumb for good performance: Where it is possible to establish wort flow at a rate of Q/5 or less, exiting wort will be chilled to within 3 °F (1.7 °C) of the available coolant temperature, as long as the cooling water flow is equal to or greater than Q. Mathematical (rather than graphical) computation of the efficiency for this rule-of-thumb operating point gives an efficiency of 98.53%. Applying equation 2 tells us that if the entering coolant temperature is 32 °F (0 °C) and the entering wort temperature 212 °F, wort exit temperature will be 2.6 °F (1.4 °C) above the entering coolant temperature, or 34.6 °F (1.4 °C). (This example shows the extremes of wort and coolant temperatures. The difference between exiting wort and entering cooling temperatures will be somewhat less when coolant temperatures are higher and wort temperatures are lower.) Because 3 °F is easier to remember than 2.6 °F, we usually speak of a less than 3 °F rise for the “Q by Q/5” operating point.* As we shall see shortly, it is not always possible to realize a wort flow of Q/5 because reducing the wort flow rate reduces Q. Sometimes lower levels of efficiency must be accepted.
| Spreadsheet Examples |
| The data from your temperature measurement experiments can be calculated in a simple spreadsheet program, like Excel (Microsoft, Bellevue, Washington). The example spreadsheets shown here are provided in two forms — one with data, and the other showing the formulas behind the data. Other spreadsheet programs will require similar formulas in the cells. Spreadsheet row and column identifiers (numbers and letters) are shown to help you correlate the numbers with the formulas that produced them. The first spreadsheet shows the experimental data set obtained from Chiller B. The first column has entries for the number of seconds required to fill a pitcher to the 1-L mark. The second column indicates the hot water inlet temperature. The third column contains the entries for the measured wort (in this experiment, boiled water) outlet temperature. The fourth column is the coolant inlet temperature. The fifth column contains wort flow rates computed from the times in the first column. The sixth column contains values for the coolant flow rate. The seventh column holds computed values for efficiency; the eighth, computed values for αL; and the last column contains the computed values of Q. Values for m and b obtained for the best linear fit to the pairs of Fw and Q are displayed in two labeled cells at the bottom of the spreadsheet. The formulas necessary to compute efficiency and Q are all given in the boxes on pp. 52–53. For clarity, the next spreadsheet shows the formulas actually used to compute the values in the previous spreadsheet. One peculiarity of Excel is that the LINEST function, used to estimate m and b, requires that two cells be dragged over to reserve space to display the two answers, the formula must then be typed in as indicated in the leftmost cell only, and then the command and enter keys must be pressed simultaneously to enter the formula. If this is not done, only the m value will be displayed. The next spreadsheet illustrates the calculation of an efficiency curve from the m and b numbers obtained using the first spreadsheet. In the second row (just below the labels) find values for the model parameters for Chiller B and the coolant flow rate (Fc). The wort flow numbers in the first column are all within the range specified for this chiller and were chosen to fill in the span with enough points to give a smooth curve and keep the spreadsheet size modest enough that it could be printed here without using too much space. Any other spacing can be used. The second column is values of Q computed from the model parameters for this chiller using equation 3. The third column contains computed values of αL computed from equation 11, in the fourth column this has been exponentiated, and in the final column are computed values of efficiency obtained from the formula of equation 12. (Note that these efficiency numbers are not the same as those plotted for Chiller B in Figure 4, because we chose to do these calculations with a coolant flow rate of 150 gal/hour rather than the 340 gal/hour used in doing the calculation for the figure.) The final spreadsheet displays the formulas, in Excel format, used in setting up the efficiency spreadsheet. |
How to Determine Q Experimentally
Now that we know the importance and usefulness of Q in evaluating chiller performance, we need to know how to obtain values of Q for our own chillers. Some values have been published, but what we need is a means of measuring the values for our own chillers.
The exercise required to determine Q for your chiller is simply a matter of heating some water to boiling, running it through the chiller, measuring the inlet and outlet temperatures and the wort and coolant flow rates, and calculating the chiller’s efficiencies at various flow rates. Finally, those values will be processed to determine Q, either with the help of a spreadsheet, a calculator or Figure 1.
*Wort temperature may exceed 212 °F by 1–2 °F, especially if the wort is of high gravity. Using 3 °F rather than 2.6 °F in the specification of maximum rise more than makes up for this added variable.
| Table I: Cooling Time and Coolant Used to Chill Wort at Various Flow Rates for a Q of 65 | |||||
| Normalized (gal/hour) | Un-normalized (gal/hour) | ||||
| Wort Flow | Coolant Flow | Wort Flow | Coolant Flow | Time for 10 Gal (min) | Coolant Used (gal) |
| 0.14 | 0.3 | 9.1 | 19.5 | 66 | 21 |
| 0.18 | 1 | 11.7 | 65 | 51 | 56 |
| 0.20 | 10 | 13.0 | 650 | 46 | 500 |
Determining efficiency values: Measure wort temperatures. Be sure to measure the wort temperatures just where the wort enters and leaves the chiller. Some chillers come with a thermometer installed in a compression “T” right at the outlet. Installing another one of these at the inlet is ideal. If no thermometer was supplied with your chiller, try piercing a small hole in the plastic wort tubing where it joins the chiller. Then insert a dial-type thermometer through the small hole in the plastic tubing with the probe along the axis of the tubing and the tip right where the wort enters/leaves the chiller. If the hole in the tubing is small enough and the fit tight enough, any leakage from the installation should be small. Some sort of sealing compound could probably be used to make the pierce point water-tight. Be sure that all thermometers have been calibrated.
Measure coolant temperature and flow rate. Turn on the cooling water full blast, and allow a few minutes for the cooling water temperature to stabilize and to ensure that the temperature is that of the well or city main and not that of the pipes in your house or brewery. Measure the flow rate by timing how long it takes to fill a container of known capacity (a 1-gal jug, for example). Getting a good measurement here could be a bit tricky because the flow rate may be high enough force water out of the exhaust hose with some violence.
Measure wort flow rate. Now allow the “wort” (boiling water) to flow from the kettle through the chiller. Get a wort flow measurement by timing how long it takes to fill an accurately calibrated container to a given mark (1 L or 1 qt is a good amount for a small chiller). The time taken for the flow measurement should be sufficient for the temperature readings to stabilize, but check to make sure that they are stable. When you are certain, record inlet and outlet temperatures.
Take a range of readings. As soon as you have a measurement pair, reduce the wort flow (by closing a valve or tightening a ‘C’ clamp onto a hose, for example) and repeat to obtain a series of measurements. The measurement set should include a slow-end wort flow with outlet temperatures within half a degree or so of the coolant temperature. The fastest flow should be as fast as the system can supply wort to the chiller.
A small pump can help you control wort flow rate and get a good range of wort flow rates and a uniform flow rate. If you use a pump, be very careful, because flow control is best achieved by throttling at the output, which pressurizes the line between the pump and the throttling device. The plastic hoses often used by home brewers become soft at boiling temperatures and can pop off their barbs unless tightly clamped, resulting in boiling water sprayed around the setup area.
Calculate efficiency. For each set of measurements calculate the efficiency using equation 1. If you wish to determine Q graphically, multiply by 100 to get a percent value; if you plan to use the formulas given at the end of the article, leave values in decimal form.
Calculating Q: Now calculate values for Q from your data pairs. This is best done using a spreadsheet (an example spreadsheet is shown in the box, “Spreadsheet Examples”), with a calculator using the equations developed later in this article (see box, “Mathematical Formulas for Q”), or graphically (using Figure 1). Although the calculations give the most accurate results, examining how this can be done graphically illustrates an important point.
Example. In one experiment, hot water flowing at 53 gal/hour was cooled from 212 °F to 61 °F (16 °C). The cooling water was at 56.5 °F (13.6 °C) with a flow rate of 290 gal/hour. These numbers give an efficiency of 0.9711 or 97.11%.
To solve for Q graphically, divide the wort flow rate by the coolant flow rate. In the example, the ratio is 53/290 = 0.1827. Next, go to the performance graph (Figure 1) and find the vertical line representing 0.1 normalized coolant flow. Move up the line until you find the value on the vertical axis that corresponds to 0.1 times the ratio of the flow rates or 0.01827 in this case. Make a mark at that point. Now go to normalized coolant flow 1.0 and move up its vertical line to 0.1827 and mark that spot. Draw a straight line between the two marks (see Figure 1). Note that any points representing the flow ratio can be used, such as (0.2, 0.03654), (0.3, 0.05481), (4, 0.7308), etc. to facilitate the drawing of the straight line.
The straight line should pass through the family of efficiency curves away from the part of the graph where they are bunched up (see Figure 1). If your straight line does not do this it is because the ratio of wort flow to coolant flow for this measurement was too high. Note this, and regard the Q value determined from this temperature pair with suspicion. Such values of Q are known to be inaccurate whether determined from a graph or by the formulas. Q is said to be “poorly observable” under these conditions.
Next, find the point at which the straight line just drawn intersects the measured efficiency curve. In our example, the efficiency was 97.11%. Because the graph shows no curve with that value, we must interpolate between the 97% and 98% curves. 97.11% is much closer to 97% than to 98%, so we try to visualize where the straight line would cross a curve parallel to the 97% curve and about one-tenth of the distance to the 98% curve. Read the value of this intersection from either axis. It appears to be at a level of about 0.26 on the wort flow axis and about 1.4 on the coolant flow axis.
Finally, take these normalized values and divide them into the actual flow rates to get estimates of Q. Dividing 0.26 into the wort flow of 53 gal/hour gives Q = 204, and dividing 1.4 into the coolant flow of 290 gal/hour gives Q = 207 as estimates for this chiller. These results are consistent within the limits of what can be expected from reading graphs and compare favorably with the value obtained from formulas (217).
Multiple readings and the straight-line fit: Determine values of Q from your other temperature data pairs and then plot them against the “wort” flow rate.
Figure 2 shows an example of what the plot might look like. These data were taken from experiments with a commercially available chiller (called Chiller A here). The chiller has a coaxial design, consisting of a 0.5-in. o.d., 0.39-in. i.d. copper tube enclosed in a 0.93-in. o.d. steel tube formed into a 5-in. (average) diameter coil of 4.5 turns. Thus, the length of the chiller if straightened out would be about 6 feet. The measured values of Q are indicated by open circles. They were obtained in two separate experiments with coolant flow of 170 gal/hour for some and 230 gal/hour for others. (Note that the determined value of Q is insensitive to changes in coolant flow rate of this