Wine pH Meter Kit. Lab Grade. High Performance. Tough.
The Milwaukee MW102 PRO+ Wine pH Meter Kit has won fans around the world with its reliable, fast and simple operation as well as its toughness and accuracy. The MW102 Wine pH Meter Kit combines the power of the MW102 meter with the special capabilities of the MA919B/1 Direct Wine Measurement pH Probe specifically designed for wine.
Summary
The Milwaukee PRO+ pH Meter is a specialist Wine pH Meter Kit combination specifically designed for the pH analysis of Wine with a Large PTFE reference that slides up for easy electrolyte purging and is refillable!
The Milwaukee PRO pH meter offers:
Accuracy
People choose the PRO+ pH Meter to improve the accuracy of their pH testing program. With two point calibration, the meter can be quickly calibrated to a higher accuracy compared with one point calibration. The MW102 meter has accuracy to ±0.02 pH. 5x more accurate than some alternative meters.
The meter comes with both a Wine specific pH probe and temperature probe allowing the meter to automatically adjust the pH reading for the effect of temperature.
The temperature probe can also be used as a very accurate thermometer.
Toughness
The rugged meter is built to take knocks.
Specialized design for pH analysis in Wine
MA919B/1 Wine probe features include a Large PTFE Reference that helps prevent wine junction stains and clogging, sliding reference that allows the user to easily purge tainted internal electrolyte, is glass with a high impedance for faster response time and is easily refillable with a screw hole on its cap.
The PRO MW102 Wine Kit also arrives complete with the Wine Start Kit 7.01, 4.01 pH calibration solutions, the MA9016 Cleaning Solution, the MA9015 Storage Solution and MA9011 electrolyte refilling solution all designed to keep your electrode in top performing condition!
The PTFE large reference junction, unlike standard electrodes, helps reduce wine stains and clogging which increases performance and accuracy for the user.
Design Features
Fast easy to read results with large digital LCD readout
Lightweight and portable
Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize
Automatic Temp. Compensation (ATC)
Automatic two-point calibration for increased accuracy
Extreme accuracy to ±0.02 pH and extended range (-2.00 pH to 16.00 pH)
Wine specific electrode with an easy-to-clean, PTFE reference
Rugged stainless temperature probe
Auto shut off and low power demand
Approx. 300 hours of continuous use
Wine Start Kit included (calibration and maintenance solutions)
Arrives complete with 4.01 & 7.01 calibration Solutions, MA9016 Cleaning Solution, MA9015 Storage Solution and MA9011 Electrolyte refilling solution.
Accuracy:±0.02 pH
Temperature Compensation:
AutomaticRange:0.00 - 12.00 pH
Calibration:Automatic
Care and Use
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction the PTFE Sliding material that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the following ways.
Cleaning and Storage
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016 Cleaning Solution for about 20 minutes.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus pH meter accurate. Also, calibrate after cleaning or a long period of storage.
Get an extremely accurate reading with this rugged bench-top pH meter. It offers the highest accuracy meter, with ATC, featuring a separate temperature probe for temperature readings independent of the electrode. The separate temperature probe allows you to check the temperature before submersing the electrode. Even though the name says "Bench-Top" it can easily be handheld. Temperature reading is in Celsius. For long term health of your electrode, use our highly recommended pH storage solution MT618. Features include: Automatic Temperature Compensation up to 50 C (122 F) 0.01 accuracy with a 0-14 pH range Push button calibration 2 year instrument warranty from Milwaukee 6 month electrode warranty 500 hour run-time on the battery Download the PDF
pH56 is a pocket pH meter with a lot of features. It has a resolution of 0.01 pH, a range of -2.00 to 16.00 pH, and an accuracy of 0.05 pH. It also reads temperature from 23.0 degrees F to 140 degrees F (-5.0-60 C), and has automatic temperature compensation. The unit is completely waterproof.
The pH56 has a stability indicator and hold function that freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through the operations. Calibration is made automatically in 1 or 2 points with memorized standard and NIST buffer sets. Auto power off saves battery power after non-use. The double-junction electrode can be replaced in a very fast and simple way! The modular design allows easy electrode and battery replacement.
Milwaukee Part Number: pH56
The Milwaukee MC110 PRO pH monitor (mid-range setpoint) offers lab grade accuracy with an easily viewable continuous check on pH levels with alarms.
Design features
Fast easy to read results with large digital LCD readout
±0.2 pH accuracy with a full pH range
3.5 to 7.5 pH alarm set point range is easily accessible on the front panel
Alarm activated when reading is above or below set point
Simple manual calibration via trimmers on the front panel
Comes with full mounting kit including probe holders
Lab grade, double junction, gel filled probe designed for low maintenance
12 VDC power supply
Small footprint of 5.9 x 3.2 x 1.35”
Lightweight monitor at approx. 5.6 oz.
Range:0.0 to 14.0 pH
Resolution:0.1 pH
Milwaukee PRO pH Probe Care
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH meter accurate. Also, calibrate after cleaning or a long period of storage.
A simple, low cost pH meter eliminates the guesswork of using pH strips.
Simple 1-point calibration, accuracy to 0.1 pH units, and a pH 0-14 range make this tester incredibly easy to live with. No more guessing at your mash pH!
Includes calibration screwdriver, batteries and user manual.
Milwaukee Part Number: pH600AQ
The Milwaukee Waterproof pH55 PRO pH/Temp. Tester is one of our most accurate cost effective, well rounded, rugged and reliable testers in the market featuring dual level LCD readouts, easily replaceable probe and extended pH ranges to meet almost any application. It's simple 1 or 2 point automatic calibration is simple-to-use and offers TWO sets of memorized buffers to select. Ideal for use in aquariums, hydroponics, horticulture, education, pools, beer and many other applications.
The Milwaukee Waterproof pH55 pH/temp. tester offers:
Accuracy
The Waterproof pH55 PRO tester is accurate to ±0.1 pH & ±0.5°C (+/-1°F) and is easy to read.
With easy 2 point automatic calibration, this pH tester is quickly calibrated to an accuracy of much more expensive meters. Simple design and rugged, it brings great value for any application. Why guess at your readings using litmus paper when you can have guaranteed accurate, digital LCD results.
Long life
The tester comes with a replaceable pH probe with a double junction probe designed for longer life.
Fast response
The probe is double junction allowing quick, accurate pH readings and respose times.
Waterproof construction
No more worries about dropping your tester while measuring. The pH55 PRO is waterproof to IP65.
Light weight
At just 3.5 ounces, the pH55 PRO is easy to handle at up to half the weight of other testers.
Ease-of-use
A large Dual Level LCD screen with easy-to-read graphic symbols, makes it easy while calibrating or reading your measurement. This takes the takes the guess work out of litmus paper.
Design features
Fast easy to read results with large digital LCD readout.
Extreme pH accuracy to ±0.1 pH with an extended pH range (-2.0 pH to 16.0 pH).
Resolution to 0.1 pH.
Lightweight and portable.
Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading.
Is fully compensated for temperature (ATC).
Simple Automatic one or two-point calibration.
Acid Based calibrations, cleaning & storage solutions use PH-START add MA9010 (10.01 cal. buffer) or M10010B if Basic cal. required.
2 Sets of pre-memorized buffers. (pH 4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Gel-filled, double junction pH electrode for low maintenance and high performance.
Over 300 hours of battery life (batteries included).
Fully waterproof to IP65.
Replaceable pH electrode Mi56P.
pH Range:-2.0 – 16.0 pH
Resolution:0.1 pH
Accuracy:±0.1 pH
Calibration:Automatic 1 or 2 point with 2 sets of pre-memorized buffers (pH 4.01, 7.01, 10.01) or (pH 4.01, 6.86, 9.18)
Care and Use
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
Here are our top four tips.
Always store upright with the cap full of MA9015 Storage solution for BEST RESULTS.
Clean your Tester regularly by soaking in cleaning solution MA9016. Cleaning Solution for about 20 minutes.
Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.
Gently stir the Tester in the sample for a faster result.
The Milwaukee MC720 PRO pH controller and pump lets you measure and adjust pH levels automatically.
Summary
The MC720US kit includes the MC122 pH controller and MP810 dosing pump to automatically monitor and fine-tune pH levels. Just set your pH parameters and let the MC720US pH Controller and pump do the rest.
The MC720US is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.
Features
Accuracy
The Milwaukee PRO pH controller offers an accuracy to ±0.2 pH with two point manual calibration.
Automation
The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.
Compatible dosing pump
The Milwaukee MP810 dosing pump (designed specifically for use with the MC122) is included in the kit.
Easy installation
The MC720 pH controller and pump kit comes with a complete mounting kit including a probe holder.
Design features
Fast easy to read current results with large digital LCD readout
Accurate to ±0.2 pH
Simple two-point calibration for increased accuracy with manual trimmers for easy adjustment
5.5 to 9.5 pH alarm set point range is easily accessible on the front panel
Alarm activated when reading is above or below set point
Comes with full mounting kit including probe holders
Lab grade, double junction, gel filled probe designed for low maintenance
6.5’ probe cables for extra flexibility
12 VDC power supply
Pump provides a maximum pressure of 1.5 bar or more than 50 feet of head pressure with a 0.39268 GPH / 9.5 GPD dosing flow.
Uptake & Discharge Tubing Material: Polyethylene, 4.92' / 1.5 m.
Black Pump Squeeze Tube Material: Norprene.
Use and Care
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.
This Milwaukee 3-in-1 Low Range combo meter allows you to measure pH, EC (conductivity) and TDS with a single meter and one single probe.
Summary
pH and TDS are critical for water conditioning and aquariums. Total Dissolved Solids in drinking water can effect clarity and taste of water. In addition, high TDS levels can effect the health of a fish in an aquarium. High concentrations of TDS can decrease clarity of water in aquariums and decrease photosynthesis in aquatic plants.
The Milwaukee MW801 PRO Low Range Combo Meter lets you easily and accurately test pH, conductivity and total dissolved solids (TDS) using a single meter and integrated probe.
Simple, portable and rugged. No more juggling multiple electrodes and wires. Automatic temperature compensaton included.
The MW801 is the ultimate solution for pH and nutrient management.
Design Features
The design of the MW801 is focused on simple operation and ruggedness. With a single probe, big screen, easy calibration, the MW801 is exceptionally simple to operate.
A tough meter build and a rugged but replaceable probe means that you can expect years of use.
The Milwaukee PRO Combo meter offers:
pH, conductivity / nutrient EC, TDS (ppm) with automatic temperature compensation.
A replaceable, integrated pH, EC, and TDS (ppm) probe with a single 3 foot cable for easy use (SE600 probe included).
A fiber junction on the pH sensor to reduce contamination when measuring fertilizer solutions.
A light weight and portable form factor at just 5.8 ounces with battery and just over 3 inches wide.
A large easy to read display.
Factory calibration with a simple, single point manual calibration for both pH and EC.
A reputation for a rugged build and long life
Specialized design for drinking water, aquaponic, and aquariums.
Care and Use
The MW801 PRO Combo Meter includes both a pH and EC sensor in the SE600 integrated probe. All pH sensors have a limited life and response time gets longer with age. EC sensors are more robust but can still be affected by residue build up. Both need maintenance. Properly maintaining your probe will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH/EC electrode before use!
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
Here are our top four tips.
Always store with the cap full of Storage Solution MA9015 for BEST RESULTS.
Clean your probe regularly by soaking in cleaning solution MA9016 for about 20 minutes.
Calibrate after cleaning and/or storage before testing to adjust for changes in the pH and EC sensor.
Gently stir the probe in the sample for a faster result.
Calibration
To ensure the meter's stated accuracy, be sure to order the Combo-Start Kit our BEST Value here: COMBO-START Kit. This has the MA9007 (230 mL bottle of 7.01 calibration Solution), MA9061 (230 mL bottle of 1,413 uS calibration Solution), MA9015 (230 mL bottle of Storage Solution), MA9016 (230 mL bottle of Cleaning Solution) all in one kit. For the TDS you will need MA9062.
Accurate. Simple. Reliable. 24/7 pH/EC/Temp Monitoring.
Why Guard when you can Monitor! The Milwaukee MC811 MAX pH/EC/Temp Monitor lets you monitor your pH/EC/Temp levels 24/7 automatically.
Summary
The MC811 MAX Monitor automatically monitors and displays pH/EC/Temp levels. Just calibrate the parameters and let the Milwaukee MAX Monitor do the rest.
The Milwaukee MC811 MAX pH/EC/Temp Monitor is preferred by people looking to know 24/7 what their pH and nutrient levels are on an ongoing basis. Common uses are nutrient tanks, Hydroponics and aquariums.
The Milwaukee MAX pH/EC/Temp Monitor offers:
Accuracy
The Milwaukee MAX Monitor offers an accuracy to ± 0.2 pH with two point manual calibration, EC accuracy of ±2% Full Scale and ±0.5 °F (0.3 °C) temperature accuracy.
Automation
Just calibrate the parameters and begin to monitor 24/7!
Easy installation
The MC811 MAX pH/EC/Temp Monitor comes with with two complete probe mounting kits.
Design features
Fast, easy-to-read current results with 3 large digital backlit LCD readouts.
Simple two-point pH calibration and one-point EC, for increased accuracy with manual trimmers for easy adjustment
Gel-filled, double junction, lab grade pH electrode for low maintenance and high performance
Low maintenance fixed EC probe
6.5’ probe cables for extra flexibility when testing
12 VDC power supply
Mount above the sample to be tested or rest on a flat surface next to the sample
Compact size of only 6.3” x 4.3” x 1.4”
Weighs only 1.2 lbs
Range:0.0 - 12.0 pH | 0.00 to 5.00 mS/cm | 14.0°F to 140.0°F
Resolution:0.1 pH | 0.01 mS/cm | 0.1°F / 0.1°C
Accuracy:± 0.2 ph | ± 2% Full Scale | ±0.5°F (±0.3°C)
Calibration:pH Manual, 2 Point (trimmer) | EC, Manual 1 point | Temp. Factory Calibrated
Use and Care
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.
This Milwaukee MW805 MAX pH/EC/TDS/Temp. 4-in-1 combo meter allows you to measure pH, EC (conductivity), TDS and Temp. with a single meter and one single probe.
Summary
pH and conductivity are critical for growers. pH can effect plant nutrient and water uptake and reduce the efficiency of fertilizer, herbicides and pesticides. Managing conductivity helps growers pinpoint fertilizer and other needs.
The Milwaukee MW805 MAX Combo Meter lets you easily and accurately test pH, conductivity and total dissolved solids (TDS) using a single meter and integrated probe.
Simple, portable and rugged. No more juggling multiple electrodes and wires. Automatic temperature compensaton included.
The MW805 MAX is the ultimate solution for pH and nutrient management.
Design Features
The design of the MW805 MAX is focused on simple operation and ruggedness. With a single probe, big screen, easy calibration, the MW805 is exceptionally simple to operate.
A tough meter build and a rugged but replaceable probe means that you can expect years of use.
The Milwaukee Combo meter offers:
pH, conductivity / nutrient EC, TDS (ppt) with automatic temperature compensation.
Selectable TDS factors from .40 to 0.8; defaulet value 0.50.
Stability indicator prompting the user when the readings stabilize.
Dedicated GLP key to store and recall data on system status.
A replaceable, Amplified Combination pH/EC/TDS/Temp probe with a single 3 foot cable (1 meter) for easy use (MA852D/1 probe included)
A cloth junction on the pH sensor to reduce contamination when measuring fertilizer solutions. Gel filled for long lasting measurments.
A light weight and portable form factor at just 9.2 ounces (260 g) with battery and just over 3 inches wide.
A large easy to read display.
Factory calibration for Temperature and simple, highly accurate, single cell automatic, one point calibration for EC and an automatic up to 5 point calibration for pH.
IP 67 rated rugged case built for field or lab applications.
Specialized design for hydroponic, aquaponic, and greenhouse growers.
Care and Use
The MW805 MAX Combo Meter includes both a pH and EC sensor in the MA852D/1 integrated probe. Both need maintenance. Properly maintaining your probe will give you fast, accurate results for longer. All pH sensors have a limited life and response time gets longer with age. EC sensors are more robust but can still be affected by residue build up.
Range:-2.00 - 20.00 pH | 0 - 4000 µS/cm | 0 - 2000 ppm (mg/L) | -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution:0.01 pH | 1 µS/cm | 1 ppm (mg/L) | 0.1°C (0.1°F)
Accuracy:±0.01 pH | ±2% Full Scale EC/TDS | ±0.5°C (±0.9°F)
Care and Use
The MW805 MAX Combo Meter includes both a pH and EC sensor in the MA852D/1 integrated probe. Both need maintenance. Properly maintaining your probe will give you fast, accurate results for longer. All pH sensors have a limited life and response time gets longer with age. EC sensors are more robust but can still be affected by residue build up.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
Here are our top four tips.
Always store with the cap full of MA9015 Storage Solution for BEST RESULTS.
Clean your probe regularly by soaking in cleaning solution.
Calibrate after cleaning and/or storage before testing to adjust for changes in the pH and EC sensor.
Gently stir the probe in the sample for a faster result.
Calibration
To ensure the meter's stated accuracy, be sure to order the Combo-Start Kit our BEST Value here: pH-START Kit. This has the MA9004 (230 mL bottle of 4.01 calibration Solution), MA9007 (230 mL bottle of 7.01 calibration Solution), MA9015 (230 mL bottle of Storage Solution), MA9016 (230 mL bottle of Cleaning Solution) all in one kit. For the EC/TDS you will need MA9061.
Sine the MAX MW805 can calibrate of to 5 pH points for HIGH accuracy, use Milwaukee calibration solutions.
The Milwaukee MW803 MAX Waterproof Low Range 4-in-1 pH/EC/TDS/Temp Tester is designed as an all-in-one solution for growers.
The Milwaukee MW803 MAX Waterproof 4-in-1 Tester offers:
Accuracy
The MW803 MAX 4-in-1 tester is accurate to ±0.05 pH, EC/TDS to 2% Full Scale and ±0.5°C / ±1°F for temperature.
With automatic calibration and 5 memorized calibration points, the tester can be quickly and easily be calibrated to a higher accuracy compared with manual calibration.
Long life
The tester comes with a replaceable pH probe with a double junction probe design for longer life.
Fast response
An exposed temperature probe is located close to the pH probe for fast temperature compensation.
Waterproof construction
No more worries about dropping your tester while measuring. The MW803 is fully waterproof to IP65.
Light weight
At just 3.5 ounces, the MW803 MAX is easy to handle at up to half the weight of other testers.
Ease-of-use
A large dual level LCD screen makes reading results easy while a stability indicator and hold function that freezes the display takes the guess work out.
Design features
Fast easy to read results with large digital dual LCD readout.
Extreme accuracy to ±0.05 pH, EC / TDS 2% Full Scale and Temperature ±0.5 °C / ±1 °F.
Range 0.00 – 14.00 pH | EC 0 to 3999 µS/cm | TDS 0 - 2000 ppm | Temperature: 0.0 to 50.0 °C / 32.0 to 122.0 °F.
Lightweight and portable at just 3.5 ounces.
Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading.
Simple push button, automatic 1 or 2 point pH calibration with 5 saved calibration points and simple 1 point EC calibration.
Acid Based calibrations, cleaning & storage solutions use PH-START add MA9010 (10.01 cal. buffer) or M10010B if Basic cal. required.
For EC calibration USE MA9061 1413 µS/cm or M10031B µS/cm.
Gel-filled, double junction pH electrode for low maintenance and high performance with exposed temp. sensor for fast readings.
Auto shut off after 8 minutes of non-use.
Mi60P Replaceable pH electrode.
Fully waterproof to IP65.
Battery life approx. 100 hour of continuous use (batteries included).
Care and Use
The MW803 PRO Tester includes both a pH and EC electrode. Both need maintenance.
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
EC sensors are more robust but can still be affected by residue build up.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
Here are our top four tips.
Always store upright with the cap full of MA9015 Storage solution for BEST RESULTS.
Clean your Tester regularly by soaking in cleaning solution MA9016. Cleaning Solution for about 20 minutes.
Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.
Gently stir the Tester in the sample for a faster result.
Lab Grade. High Performance. Automated. Tough.
The Milwaukee MW150 MAX 3-in-1 pH/OPR/Temp. Bench Meter has won fans around the world with its reliable, fast, simple operation as well as a tough, sleek, lightweight design with a small lab space footprint. It is accurate to ±0.01 pH with automatic or manual temperature compensation, and built in dedicated GLP key. In addition, up to 3-point automatic calibration and 7 selectable buffer standards makes the MW150 MAX ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
Summary
The Milwaukee MW150 MAX 3-in-1 PRO pH/ORP/Temp Bench Meter is preferred by people testing all types of samples viscus or not, in a variety of applications that cause other pH meters and electrodes to fail. The MA917B/1 Milwaukee double junction electode is refillable and easy to clean. From brewers and wine makers to hydroponic growers, labs and water treatment, the MW150 MAX is your Bench Meter for fast, accurate readings.
The Milwaukee MW150 MAX pH Bench Meter offers:
Accuracy
People choose the MW150 MAX 3-in-1 pH/ORP/Temp Meter to improve the accuracy of their testing program. With up to 3 point calibration and 7 standard buffer choices, the meter can be quickly calibrated to a higher accuracy compared with 1 or 2 point calibration. The MW150 MAX Bench Meter is accurate to ± 0.01 pH. 5x more accurate than some alternative meters.
The meter comes with a double junction pH electrode (included) and temperature sensor MA831R (included) allowing the meter to automatically adjust the pH reading for the effect of temperature (ATC).
The meter can also be used as a very accurate thermometer with accuracy +/-0.4°C | +/-0.8°F.
Toughness
The rugged meter is built to take knocks and is sleek and lightweight .
Low Maintenance
The MW150 MAX pH/OPR/Temp Bench Meter comes with the Milwaukee refillable glass MA917B/1 pH electrode and has a BNC connector allowing easy interchange to any pH Milwaukee electrode. This is Milwaukee's top selling lab grade electrode for a reason. Designed to be both low maintenance (refillable) and able to withstand more challenging samples (double junction). The MA917B/1 is ideal for use in beer making, winemaking and hydroponics, environmental labs and many other applications.
Design Features
Fast easy to read results with large dual-level digital LCD readout
Extreme accuracy and extended range
Lightweight and small bench footprint
Refillable, double junction, lab grade pH electrode for low maintenance and high performance
Rugged stainless temperature probe
Automatic Temp. Compensation (ATC)
Up to three-point automatic calibration
Up to 7 selectable pH calibration buffers
Built-in rechargeable battery with 8 hours battery life (battery included)
Auto-off feature to prolong battery life
Alphanumeric LCD for intuitive information display
Internal clock and date to keep track of different time-dependent functions
Dedicated GLP key to store and recall data on system status
3’ probe cables for extra flexibility
MA917B/1 pH electrode & MA831R Included.
ORP probe sold separately.
Care and Use
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Range:-2.00 to 20.00 pH | ±2000.0 mV | -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution:0.01pH | 0.1mV | 0.1°C (0.1°F)
Accuracy:±0.01 ph | ±1 mV | ±0.4°C |±0.8°F
Care and Use
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the following ways.
Cleaning and Storage
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Storage
To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning an Maintenance
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016 for about 20 minutes. Also:
Inspect the electotrode for damage or scratches, if present replace the electrode.
Inspect the cable. The connection cable and insulation must be intact.
Connectors should be clean and dry.
Rinse off salt deposits with water or DI water.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus Bench pH Meter accurate. Also, calibrate after cleaning or a long period of storage. For BEST value on calibration, cleaning and storage solutions order pH-START. If you need to calibrate at 10.01 point order MA9010.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
MA9010 is a lab grade pH 10.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing buffers.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 10.01 Calibration Buffer Solution (230 mL)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light with air tight, tamper proof cap
Ideal for fast accurate calibration
Simply open, pour into a beaker or container and insert the tester or electrode to start the calibration process.
A replacement electrode for the MT608 & MT609 pH meter. The electrode is the consumable portion of the pH meter which actually makes the measurement. All pH electrodes wear out over time and must be replaced. If your meter is having trouble calibrating or the reading drifts then a bad electrode is the likely culprit. Download the PDF Milwaukee Part Number: SE220
Accurate. Simple. Reliable. 24/7 pH Control.
The Milwaukee MC122 PRO pH controller lets you measure and adjust pH levels automatically.
The MC122 controller automatically monitors and fine-tunes the pH levels. Just set your pH parameters and let the MC122 do the rest. The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.
The MC122 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.
Features
Accuracy
The Milwaukee PRO pH controller offers an accuracy to ±0.2 pH with two point manual calibration.
Automation
The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.
Compatible dosing pump
Milwaukee offers the MP810 dosing pump
Easy installation
The pH Controller comes with a complete mounting kit including a probe holder.
Design features
Fast easy to read current results with large digital LCD readout
Accurate to ±0.2 pH
Simple two-point calibration for increased accuracy with manual trimmers for easy adjustment
5.5 to 9.5 pH alarm set point range is easily accessible on the front panel
Alarm activated when reading is above or below set point
Comes with full mounting kit including probe holders
Lab grade, double junction, gel filled probe designed for low maintenance
6.5’ probe cables for extra flexibility
12 VDC power supply
Small footprint of 5.9 x 3.2 x 1.35”
Lightweight monitor at approx 6.3 oz.
Use and Care
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Store the pH probe in storage solution MA9015. Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.
This best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.
The Milwaukee MW151 MAX 3-in-1 PRO pH/ORP/Temp Bench Logging Meter is preferred by people testing all types of samples viscus or not, in a variety of applications that cause other pH meters and electrodes to fail. The logging feature allows log-on-demand and log-on-stability features that ensure all readings are accurate and not entered incorrectly. The MA917B/1 Milwaukee double junction electode is refillable and easy to clean. From brewers and wine makers to hydroponic growers, labs and water treatment, the MW151 MAX is your Bench Logging Meter for fast, accurate readings.
Accuracy
People choose the MW151 MAX 3-in-1 PRO pH/ORP/Temp Portable Logging Meter to improve the accuracy of their testing program. With up to 5 point calibration and 7 standard buffer choices (2 custom buffers also), the meter can be quickly calibrated to a higher accuracy compared with one or two point calibration. The MW151 MAX meter is accurate to ± 0.002 pH. 8 x more accurate than some alternative meters.
The meter comes with a refillable, glass, double junction pH electrode and MA831R temperature sensor allowing the meter to automatically adjust the pH reading for the effect of temperature (ATC).
The meter can also be used as a very accurate thermometer with accuracy +/-0.4°C (+/-0.8°F).
Low Maitenance
The MW151 MAX pH/OPR/Temp Bench Logging Meter comes with the Milwaukee glass, double junction MA917B/1 pH electrode. This is Milwaukee's top selling lab grade electrode for a reason. Designed to be both low maintenance (refillable) and able to withstand more challenging samples (double junction). The MA917B/1 is ideal for use in beer making, winemaking, hydroponics, laboratories and many other applications.
Features:
Fast easy-to-read results with large duel level digital LCD readout.
Extreme accuracy to ±0.002 pH | +/- 1 mV OPR | +/- 0.4°C (+/-0.8°F).
Extended pH range (-2.00 pH to 20.00 pH / -2.000 to 20.000 pH).
Lightweight, sleek design with small benchtop footprint.
Simple easy-to-use logging and USB download functions, manual or on stability up to 1,000 logs.
Electrode diagnostics feature checks and displays the condition of the pH electrode.
Easy measurement: just place the electode and temperature probe in the sample, gently stir and wait for the reading to stabilize.
Simple push button, automatic up to 5 point calibration for increased accuracy.
Up to 7 Standard calibration solutions (1.68, 4.01, 6.86,7.01, 9.18, 10.01 and 12.45) and 2 custom choices.
Refillable, glass, double junction lab grade pH electrode for low maintenance and high performance with a screw on cap to ensure proper storage.
Built-in rechargeable battery with 8 hours battery life (battery included).
Selectable Auto-off feature.
Alphanumeric LCD display messages for friendly, intuitive information, warnings and error messages.
Internal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).
3 feet probe cables for extra flexibility when testing.
Care and Use
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing Bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference Junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the following ways.
Storage
To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning and Maitenance
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution. Also:
Inspect the electotrode for damage or scratches, if present replace the electrode.
Inspect the cable. The connection cable and insulation must be intact.
Connectors should be clean and dry.
Rinse off salt deposits with water or DI water.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus pH meter accurate. Also, calibrate after cleaning or a long period of storage.
Specifications:
pH Range: -2.00 to 20.00 pH / -2.000 to 20.000 pH
ORP Range: ±2000.0 mV
Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
Resolution: 0.01 pH / .001 pH
Resolution: 0.1mV
Resolution: 0.1°C / 0.1°F)
Accuracy: ±0.01 pH / ±0.002 pH @ 25°C / 77°F
Accuracy: ±1mV
Accuracy: ±0.4°C |±0.8°F
pH Calibration: up to 5 point automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers
Temperature Compensation: Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual
pH electrode: MA917B/1 glass, double junction pH electrode (supplied)
Temperature probe: MA831R (included)
Logging: Maximum 1,000 samples (stored in up to 100 lots) / on demand, 200 samples on stability, 200 samples/ Interval logging, 1000 logs
PC Connectivity: 1 USB Port, 1 micro USB port
Power supply: 12VDC, 5 VDC USB Adapter (included)
Battery life: Approx. 8 hours of use
Auto-off: Selectable 5, 10, 30, 60 min. or off
Environment: 0 to 50°C / 32 to 122°F; max RH 95%
Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
Weight: 0.9 kg / 2.0 lbs.
The Milwaukee MW600 PRO Portable Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.
The Milwaukee PRO DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists and educators to fish farmers and koi pond owners.
Design Features
Fast, easy-to-read results with large digital LCD readout.
Repeatable, accuracy to ±1.5% FS.
Lightweight and portable.
Simple 2 point open air calibration (see video below).
Uses MA840 reinforced polarographic probe (ABS plastic construction), with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor MA841.
5 o-rings, membranes and one protective cap included.
Electrolyte Solution MA9071.
10 feet probe cable for extra flexibility when testing
70 hours of battery life with continuous use (battery included) with low battery warning
Care and Use
“Open Air” Calibration Procedure
1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.
2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.
3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane on to the probe.
5. Let stablize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.
You are now calibrated.
Extra tips
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
The MA911B/2 probe is lab grade, gel-filled pH probe for use with Milwaukee Monitors and Controllers.
Top Design Features:
Double Junction
The double junction junction design reduces the risk of clogging.
Spherical Glass Tip
The spherical glass tip provide the largest possible surface area for faster results.
Resin Body
The Polypropylene Resin body is tough to withstand accidental knocks and also protects the glass sensing bulb. It's high chemical resistance properties makes it ideal for Industrial applications, in-line applications and strong acids and bases.
Extended cable
Offers a 6.6' cable for increased flexibility in measuring.
Use and Care
pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.
You can extend the life of your pH electrode in the following ways:
Storage
The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Storing in pH probe storage solution or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibiration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning
Residue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO pH meter accurate. Also, calibrate after cleaning or a long period of storage.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
MA9004 is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing buffers.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 4.01 Calibration Buffer Solution (230 mL)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light with air tight, tamper proof cap
Ideal for fast calibration
Simply open, pour into a beaker or container and insert the tester or electrode to start the calibration process.
The Milwaukee MW190 MAX Bench Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.
The Milwaukee MW190 MAX DO Bench Meter is preferred by people looking for lab level accuracy without the high cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, education, water treatement plants and laboratories.
Design features
Fast, easy-to-read results with large digital LCD readout.
Repeatable, accuracy to ±1.5% FS.
Lightweight and has a small benchtop footprint.
Single offset or dual point slope with open air 100% saturation calibration.
Altitude and Salinity compensation.
Automatic temperature compensation.
Uses MA845 (included) reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor
5 o-rings, membranes and one protective cap included
2 meter probe cable for extra flexibility when testing
Logging up to 50 samples.
12 VDC power supply.
Easy RS232/USB opto-isolated
Complete with DO probe, initial calibration solutions and cables.
MA841 Replacement Membranes.
D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:
Range:0.00 to 45.00 mg/L (ppm) O2 | 0.0 to 300.0 % O2| Temp. -5.0 to 55.0°C / 23.0 to 131.0°F
Resolution:O2 0.01 mg/L (ppm) | 0.1% O2 | Temperature 0.1°C / 0.1°F
Accuracy:O2 ±1.5% of Full Scale| Temperature ±0.4°C (±0.8°F)
Calibration:Automatic, single (offset) or dual with slope 100% saturated air
Care and Use
Probe Preparation Calibration Procedure
D.O. Probes are shipped dry: To hydrate the probe and prepare it for use, connect it to the meter and procede as follows:
Remove the the red and black cap. This cap is used for protection during shipping.
Wet the sensor by soaking the bottom 2.5 cm of the probe in electrolyte (MA9071) for 5 minutes.
Rinse the membrane (supplied with meter) with electrolyte solution while shaking it gently. Refill with clean electrolyte solution.
Gently tap the sides of the membrane with the fingertip to ensure that no air bubbles remain trapped. To avoid damaging the membrane, do not tap the membrane directly on the bottom.
Place the O-Ring (suppield with membranes) properly inside the membrane cap.
With the sensor facing down, screw the cap clockwise. Some electrolyte solution will overflow.
Turn the unit on use on/off key.
All LCD tags are displayed and a beep is heard while the instrument performs a test.
The "COND" message will be displayed for about 45 seconds to inform the user that the probe is in auto-conditioning mode (automatic polarization).
Once "COND" dissappears, the probe is polarized and the instrument can be calibrated.
Calibration Offset Procedure
Remove the clear protective cap.
Submerge the probe in MA9070 zero oxygen solution and stir for about 2-3 minutes.
Press CAL. The "WAIT" tag will blink on the LCD until reading is stable.
When the reading is stable, "READY" & "ACCEPT" tags are blinking. Press ACCEPT to confirm the "0.0%" D.O. calibration.
NOTE: When the instrument is not in use, place the CLEAR plastic cap (supplied with probe) over the membrane.
Extra tips
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
Always use MA841 membranes ONLY.
Water chemistry is key to brewing the best beer possible, and that's where a pH meter becomes an essential tool Measure your strike water's pH and make informed brewing salt additions to provide the ideal environment for enzymatic activity during the mash Digital display is easy-to-read and provides instant test results—no need to do a color comparison like with pH strips Automatic Temperature Compensation adjusts the results based on the temperature of the sample so you don't need to cool the sample before taking a reading Electrode is protected by a waterproof cap so your storage solution won't evaporate and dry out the electrode The KegLand pH Meter will get you a very accurate reading with its 0.01 pH resolution. The calibration process couldn't be easier to perform, just place the probe in the buffer solution closest to pH of the sample you'll be testing and press the button! This pH meter also includes ATC (Automatic Temperature Compensation) so you don't have to get your sample all the way down to room temperature before you take your reading. 3-point calibration allows this unit to be calibrated at three different standard levels - 4.00, 6.86 or 9.18. These standards are included with the pH meter, and refill packs are also available. The pH meter features a replaceable probe in case yours is lost or damaged. Homebrewing can be a tough environment for your pH probe so we feel you shouldn't have to buy a whole new pH meter everytime your probe breaks. The cap that holds the probe storage solution has a very tight seal and should prevent your probe from drying out while not in use. Don't worry about getting this meter wet either, because the entire unit is waterproof! Features: Replaceable probe ATC (Automatic Temperature Compensation) Waterproof electrode cap Accurate to 0.01 pH Easy 3 point calibration LR4/AG13 batteries included Kegland Part Number: KL04169 NOTE: Upon first time use prior to calibration, rehydration of the electrode with MT624Bis essential to get an accurate reading for correct calibration.
The Milwaukee MW605 MAX Galvanic Portable Waterproof Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.
The Milwaukee MW605 MAX DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists, educators, fish farmers, koi pond owners, water treatement plants and labs.
Design Features
Fast, easy-to-read results with large digital LCD readout.
Galvanic probe means no conditioning time.
Repeatable, accuracy to ±1.5% of reading.
Water Proof IP67 Rated.
Lightweight and portable.
Simple 1 or 2 % saturation calibration points at 100% (water saturated air) and 0% (zero oxygen solution).
Dedicated GLP key to store and recall data on system status.
Available log space for up to 1000 records.
Logged data export via USB cable.
Altitude and Salinity compensation.
Automatic temperature compensation °F & °C.
Uses MA860 (included) reinforced Galvanic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor.
2 O-rings MA861, membranes and one protective cap included.
Electrolyte MA9072S 30 mL
10 feet probe cable for extra flexibility when testing.
3 x 1.5 volt akaline AA battery (battery included) aprox. 200 hours of battery life with continuous use with low battery warning.
Range:0.0 to 45.00 mg/L (ppm) O2 | % Saturation O2 0.0 to 300.0% | Temp. -20.0 to 120.0°C / -4.0 to 248.0°F
Resolution:O2 0.01 mg/L (ppm) | % Saturation O2 0.1% | Temperature 0.1°C / 0.1°F
Accuracy:O2 ±1.5% of reading ±1 digit| Temperature ±0.4°C (±0.8°F)
Calibration:One or Two % Saturation calibration points 0% (MA9070) and 100% (water saturated air)
Care and Maintenance
Probe Maintenance:
The silver cathode should always be bright and untarnished. If it is tarnished or stained, the cathode should be cleaned gently witha lint-free cloth.
Rinse the probe with deionized or distilled water.
Replace the membrane cap using fresh electrolyte.
Recalibrate meter.
Membrane Maintenance:
For accurate and stable measurements, perfect condition of the membrane surface is needed. Protect the thin membrane from scratches, abrasion or contact with solids.
If no measurements are taken for a few hours, protect the membrane with the plastic protective cap.
If fouled, rinse it carefully with distilled or deionized water. If damaged, replace the membrane cap.
Note: Change the membrane every 8 weeks or more frequently if used in a specially fouling environment. Check and replace the electrolyte fill solution every 4 weeks.
Storage:
After taking measurements, switch the meter off and clean the probe before storage. When not in use the probe should be stored with the plastic cap on.
For short term storage, the probe can also be stored in a beaker of deionized water with the protective plastic cap removed.
For long term storage, the probe should be stored dry:
Disconnet the probe from the meter.
Unscrew the membrane cap.
Remove any electrolyte solution from the cap.
Rinse the probe anode/cathode assembly with distilleed water and blot dry.
Screw the membrane cap onto the probe until the membrane cap is hand tight.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 10.01 Calibration Buffer Solution - 20 mL (box of 25)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Color coded for easy identification
Double Junction, refillable glass electrode with BNC connector and 1m cable. Replacement for the electrode that is included with the Milwaukee MW151 MAX pH/ORP/Temp Logging Bench Meter. The electrode is the consumable portion of the pH meter which actually makes the measurement. All pH electrodes wear out over time and must be replaced. If your meter is having trouble calibrating or the reading drifts then a bad electrode is the likely culprit.
Milwaukee Part Number: MA917B/1
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
MA9007 is a lab grade pH 7.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing buffers.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 7.01 Calibration Buffer Solution (230 mL)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light with air tight, tamper proof cap
Ideal for fast accurate calibration
Simply open, pour into a beaker or container and insert the tester or electrode to start the calibration process.
M10004B is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing calibration solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 4.01 Calibration Buffer Solution - 20 mL (box of 25)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Color coded for easy identification
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
Design Features
pH 7.01 Calibration Buffer Solution - 20 mL (box of 25)
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Color coded for easy identification
The Milwaukee MA905B/3 is a replacement pH Probe for any Milwaukee meter that uses a BNC connector. Using the BNC connection, the probe connects quickly and tightly with no worries of slipping off.
The MA905B/3 has a rugged body (PVC), comes with a 3 meter (9.8') cable, BNC connector, and can withstand up to 6 bar of pressure (meter(s) sold separately).
Lab Grade, Easy to Use, High Performance.
Milwaukee MI415 PRO Turbidity Meter is for users demanding fast, reliable, repeatable results with ease of use.
The Milwaukee MI415 PRO Turbidity features easy 3 point FNU calibration. The calibration points are 0, 10 and 500 FNU (Formazine Neophelmetric Unit). Calibration is automatic and fast with easy operation and a rugged meter design.
The Milwaukee MI415 PRO Turbidity Meter is ideal for users in aquaculture, waste and drinking water treatment, environmental labs and many other applications. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
The Milwaukee PRO MI415 Turbidity Meter offers:
Speed & Accuracy
The MI415 microprocessor delivers fast results with accuracy of ±5 FNU or 5% of the reading (whichever is greater) and is repeatable.
Easy To Use and Toughness
This rugged meter is designed to take knocks. It's low maintenance design paired with easy to use reagents makes the MI415 ideal for everyone from educators and aquaculture, brewers, environmental professionals to water treatment and food processing.
Design features
Fast easy to read results with large digital LCD readout.
Accurate to ±0.5 FNU or 5% of reading (whichever is greater).
Lightweight and portable.
Tungsten Lamp for high accuracy.
The unit of measure adopted by the ISO Standard is the FNU (Formazine Nephelometric
Unit) and by EPA is NTU (Nephelometric Turbidity Unit).
Easy measurement: just fill a cuvette with the sample after calibration, insert the cuvette, then press read and the reading displays on the large LCD.
Simple easy-to-use calibration cuvettes.
Easy 1-2-3 instruction steps.
Auto shut off after 5 minutes of non-use, 9 volt (battery included).
Replacement Glass Vials: MI0011
Replacement Caps for Vials: MI0012
Replacement Reagents: Mi515-100.
Range:0.00 to 50.00 (FNU) | 50 to 1000 (FNU)
Resolution:0.01 (FNU) | 1 (FNU)
Accuracy:±0.5 (FNU) or 5% reading (whichever is greater)
Built In Timer
MI415 PRO Turbidity Meter has a built in timer that ensures appropriate reaction time is used for the chemical reaction. At the end of the timer, the meter will automatically take the reading. This feature ensures consistency across multiple users.
Cuvette Chamber
The MI415 has a built in indexing indent on the meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Error Messaging
The MI415 has built in error messaging display alerts. This helps the user ensure no mistakes are made in the testing process. Messages include no cap, over range and under range, light source errors and zero cal error to ensure the user has the most accurate error free readings.
Calibration
The MI415 has a simple to use 3 point (FNU) calibration at 0, 10 and 500 (FNU). Simply insert the standard sample cuvette into the chamber, index the cuvette and follow the 3 steps. Your calibration is complete.
Thousands of food and beverage professionals and hobbyists have moved from less accurate and less precise optical refractometers to digital Brix measurement. Milwaukee’s MA871 is the ideal tool for winemakers, brewers, fruit and vegetable growers, maple syrup producers, and food producers.
The MA871 is fast and easy-to-use with a response time under 2 seconds. Maintenance is a breeze with an easy-to-clean sealed flint glass prism and stainless steel well. The measurement technique and temperature compensation employ methodology recommended in the ICUMSA Methods Book (internationally recognized body for sugar analysis).
Summary
The Milwaukee digital BRIX refractometer is temperature compensated with a 0 to 85 percent BRIX range and ±0.2 percent accuracy. It is easy to use with simple two button operation and fast with a response time under 2 seconds. Maintenance is a breeze also with an easy-to-clean sealed flint glass prism and stainless steel well.
Design Features
Fast, accurate results with digital dual level LCD readout
Easy measurement with just 2-3 drops of sample needed
Results in less than 2 seconds
Simple one-point calibration using distilled or deionized water
Easy-to-clean stainless steel sample well
Meter rated to IP65 as “dust tight” and protected against water jets
Battery percent level indicator with automatic shut-off (batteries included)
Automatic Temp. Compensation (ATC)
Hard plastic case sold separate: MA800.
Range:0 to 85% Brix
Resolution:0.1% | 0.1°C (0.1°F)
Accuracy:±0.2% Brix | ±0.3°C | ±0.5°F
Lab Grade. Accurate. Simple. Automated.
The Milwaukee MI456US PRO TA Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The instrument comes with a preprogrammed analysis method designed for Total Titratable Acidity measurements on wine. The MI456US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode. The MI456US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI456US uses a preprogrammed method and lab grade pH electrode combined with an algorithm to determine the end of the titration reaction.
Summary
The Milwaukee MI456 PRO TA Mini Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.
The Milwaukee PRO TA Mini Titrator offers:
Accuracy
The MI456 PRO Mini Titrator is accurate to 5% of the reading with a resolution of 0.1 g/L with a range of 0.0 to 25.0 g/L of tartaric acid. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade pH electrode.
Simplicity
The MI456 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.
Automated Operation
The MI456 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI456 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.
Design Features
Easy measurement: just measure the wine sample, add the reagents as directed, prepare pH probe and pump, add the stabilizer and start the titration by pressing the start button.
Refillable, double junction lab grade pH electrode.
Automatic temperature compensation.
Range: 0.0 to 25.0 g/L of tartaric acid
Accuracy: 5% of reading
Method: Acid-base titration
700 rpm built-in stirrer.
Simple and reliable peristaltic pump that ensure high dosing repeatability.
Compact 8.2 x 8.4” footprint.
Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.
Replacement Kit: Mi556-KIT. Individual Reagent Bottles.
Replacement pH electrode: MA919B/1.
Care and Use
pH electrodes usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.
Sensing Bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.
Reference Junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.
You can extend the life of your pH electrode in the following ways.
Cleaning and Storage
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Storage
To minimize clogging the pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Storing in pH probe storage solution MA9015 or pH calibration buffers will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning an Maintenance
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also:
Inspect the electrode for damage or scratches, if present replace the electrode.
Inspect the cable. The connection cable and insulation must be intact.
Connectors should be clean and dry.
Rinse off salt deposits with water or DI water.
Calibration
The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your MI456 Mini-Titrator readings accurate. Also, calibrate after cleaning or a long period of storage.
Accurate. Simple. Reliable. 24/7 Conductivity (EC) Monitoring.
The Milwaukee MC310 PRO Conductivity (EC) monitor lets you measure EC levels automatically and alerts with an alarm when out of the set point range.
Summary
The MC310 EC automatically monitors your EC levels. Just set your EC parameters and let the Milwaukee EC monitor do the rest. The monitor has a set point range from 1.0 to 5.0 mS/cm with alarms that activate when readings are higher or lower than set point.
The MC310 is preferred by people looking to dial in their testing program when they have a need to maintain levels. Common uses are nutrient tanks, hydroponics, and horticulture.
Features
Accuracy
The Milwaukee PRO EC monitor offers an accuracy to ±2% full scale.
Automation
The monitor has a set point range from 1.0 to 5.0 mS/cm with alarms that activate when readings are higher or lower than set point.
Easy installation
This EC monitor comes with a complete mounting kit including a probe holder.
Design features
Fast easy to read current results with large digital LCD readout
Accurate to ±2% full scale
Simple one-point calibration with manual trimmers for easy adjustment
1.0 to 5.0 mS/cm alarm set point range is easily accessible on the front panel
Alarm activated when reading is above or below set point
Comes with full mounting kit including probe holders
MA812/2 hardwired EC probe
6.5’ probe cables for extra flexibility
12 VDC power supply
Range:0.0 - 10.0 mS/cm
Resolution:0.1 mS/cm
Calibration:Manual, 1-point
The Milwaukee EC59 PRO Waterproof EC/TDS/Temperature Tester is designed for aquaculture, food, wine, laboratory, water treatment, and many other applications.
Keeping EC in your target range helps to achieve better results.
Design Features
Measures conductivity and TDS with Automatic Temp. Compensation (ATC).
EC59 features the ideal range for aquaculture and other applications.
Units easily convertible to other ranges.
Factory calibrated with the ability to recalibrate if needed.
Use MA9061 or M10031B 1413 µS/cm.
Replaceable electrode Mi59P.
Fully waterproof to IP65.
Approx. 100 hours of continuous use (batteries included).
EC Range:0 - 3999 uS/cm | 0 to 2000 ppm | 0.0 to 60.0°C (32.0 to 140.0°F)
Resolution:1 uS/cm / 1 ppm / 0.1 C / 0.1 F
EC/TDS/Temp Accuracy:2% Full Scale | +/-0.5°C (+/-1F)
Temperature Compensation:Automatic
Care and Use
Maintenance
EC electrodes can develop nutrient build up over time. To minimize build up, always rinse the probe in fresh tap water after every use.
Converting EC to TDS
The Milwaukee PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC/TDS can converted. Different scales include the 500 scale, 650 scale and the 700 scale.
Your µS/cm reading can be approximately converted to other scales as shown in the examples below.
2.00 mS/cm = 2000 µS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 µS/cm = 1400 ppm on the 442 scale or .70 factor scale
Lab Grade. Accurate. Simple. Automated.
The Milwaukee MI455US PRO SO₂ Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation. The MI455US uses a piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode. Using a modified Ripper method, this mini-titrator does not rely on color change but uses potentiometric detection. The MI455US automatically dispenses the titrant, determines the endpoint, and completes the calculations in a fraction of the time needed for a manual titration. The MI455US uses a preprogrammed method and specialized ORP electrode combined with an algorithm to determine the end of the titration reaction.
Summary
The Milwaukee MI455 PRO SO2 Mini-Titrator is preferred by wine makers seeking results faster with lower costs and simple operation.
The Milwaukee PRO SO2 PRO Mini-Titrator offers:
Accuracy
The MI455 PRO Mini-Titrator is accurate to 5% of the reading with a resolution of 1 ppm with a range of 0-400 ppm. The titrator uses piston-driven pump for accurate dynamic dosing, a built-in magnetic stirrer for a faster reaction and lab grade platinum-ringed ORP electrode.
Simplicity
The MI455 PRO Mini-Titrator is designed to for simple one button operation with pre-standardized titrant and pre-measured reagents for easy set up.
Automated operation
The MI455 PRO Mini-Titrator uses a precision piston style dosing pump that dynamically adjusts the dosing volume as the voltage changes. With the MI455 PRO Mini-Titrator, you get a faster result with no need for manual intervention or calculation.
Design Features
Measure both free and total SO₂
Easy measurement: just measure the wine sample, add the reagents as directed, prepare ORP probe and pump, add the stabilizer and start titration by pressing the start button.
Refillable, double junction lab grade ORP electrode.
700 rpm built-in stirrer.
Simple and reliable peristaltic pump that ensure high dosing repeatability.
Compact 8.2 x 8.4” footprint.
Built-in algorithm to analyze the shape of the electrode response and to determine the reaction completion that automatically completes the analysis, makes all necessary calculations and assures a user friendly interface.
Replacement Reagent Kit: Mi555-KIT. Individual bottle here: Individual Reagent Bottles.
Replacement ORP Electrode: MA924B/1.
Care and Use
ORP electrodes usually start performing poorly because of problems with the probe. The two parts of the ORP probe that cause problems are the glass sensing bulb and the reference junction.
Sensing Bulb
The glass bulb loses sensitivity with use and will eventually fail. This is true of all ORP probes.
Reference Junction
The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the ORP electrode will no longer function.
You can extend the life of your ORP electrode in the following ways.
Cleaning and Storage
All ORP sensors have a limited life and response time gets longer with age. Properly maintaining your ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Storage
To minimize clogging the ORP probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.
Storing in ORP probe storage solution MA9015 will help address both these issues. Do not store in tap water or DI water. This will damage the sensitivity of the probe.
The best way to store the probe is with the probe's cap filled with storage solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.
Cleaning an Maintenance
Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016. Also:
Inspect the electrode for damage or scratches, if present replace the electrode.
Inspect the cable. The connection cable and insulation must be intact.
Connectors should be clean and dry.
Rinse off salt deposits with water or DI water.
Accurate. Simple. Reliable. 24/7 pH Control.
The Milwaukee MC311 PRO Conductivity (EC) controller lets you measure and adjust EC levels automatically.
Summary
The MC311 EC controller automatically monitors and fine-tunes EC levels. Just set your EC parameters and let the Milwaukee EC Controller do the rest.
The MC311 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.
Features
Accuracy
The Milwaukee PRO EC controller offers an accuracy to ±2% full scale.
Automation
The controller provides a control range of 0.0 to 10.0 mS/cm with alarms that activate when readings are higher or lower than set point.
Compatible dosing pump
Milwaukee also offers the optional MP810 dosing pump
Easy installation
This EC Controller comes with a complete mounting kit including a probe holder.
Design features
Fast easy to read current results with large digital LCD readout
Accurate to ±2% full scale
Simple one-point calibration with manual trimmers for easy adjustment
0.8 to 2.8 mS alarm set point range is easily accessible on the front panel
Alarm activated when reading is above or below set point
Comes with full mounting kit including probe holders
MA812/2 hardwired EC probe
6.5’ probe cables for extra flexibility
12 VDC power supply