{"product_id":"milwaukee-mc122-pro-ph-controller","title":"Milwaukee MC122 PRO pH Controller","description":"\u003cp\u003e\r\n\t\u003cstrong\u003eAccurate. Simple. Reliable. 24\/7 pH Control.\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe Milwaukee MC122 PRO pH controller lets you measure and adjust pH levels automatically.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\tThe MC122 controller automatically monitors and fine-tunes the pH levels. Just set your pH parameters and let the MC122 do the rest. The controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\tThe MC122 is preferred by people looking to dial in their testing program when they have an ongoing need to maintain levels. Common uses are nutrient tanks and aquariums.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe Milwaukee PRO pH controller offers an accuracy to ±0.2 pH with two point manual calibration.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eAutomation\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe controller provides a control range of 5.5 to 9.5 pH with alarms that activate when readings are higher or lower than set point.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eCompatible dosing pump\u003c\/strong\u003e\u003cbr\u003e\r\n\tMilwaukee offers the MP810 dosing pump\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eEasy installation\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe pH Controller comes with a complete mounting kit including a probe holder.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eDesign features\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cul\u003e\r\n\t\u003cli\u003e\r\n\t\tFast easy to read current results with large digital LCD readout\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tAccurate to ±0.2 pH\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tSimple two-point calibration for increased accuracy with manual trimmers for easy adjustment\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\t5.5 to 9.5 pH alarm set point range is easily accessible on the front panel\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tAlarm activated when reading is above or below set point\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tComes with full mounting kit including probe holders\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tLab grade, double junction, gel filled probe designed for low maintenance\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\t6.5’ probe cables for extra flexibility\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\t12 VDC power supply\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tSmall footprint of 5.9 x 3.2 x 1.35”\u003c\/li\u003e\r\n\t\u003cli\u003e\r\n\t\tLightweight monitor at approx 6.3 oz.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eUse and Care \u003c\/strong\u003e\u003cbr\u003e\r\n\tpH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eSensing bulb\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eReference junction\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH probe will no longer function.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\tYou can extend the life of your pH electrode in the following ways.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eStorage\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\tStore the pH probe in storage solution MA9015.  Only use tap water short-term if MA9015 is not immediately available and NEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\tThis best way to store the probe is with the probe's cap filled with MA9015 Storage Solution and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eCleaning\u003c\/strong\u003e\u003cbr\u003e\r\n\tResidue from the sample can impact the sensitivity of the sensing bulb and block the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking the probe in MA9016 Cleaning Solution for about 20 minutes.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003cbr\u003e\r\n\tThe pH sensing bulbs become less sensitive over time so make sure that you are calibrating reguarly to keep your PRO pH controller accurate. Also, calibrate after cleaning or a long period of storage.\u003c\/p\u003e\r\n\u003cp\u003e\r\n\t \u003c\/p\u003e\r\n","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":52623211692321,"sku":"MT8125","price":208.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/7521\/2321\/files\/67259.jpg?v=1777576293","url":"https:\/\/morebeer.com\/products\/milwaukee-mc122-pro-ph-controller","provider":"MoreBeer!","version":"1.0","type":"link"}