This is just the same FE610 controller without any wiring. For the "Do It Your Self" person or for hard wiring into your application. It comes with a manual and wiring diagram, but you must have electrical knowledge. If you are unsure you are best purchasing the pre-wired FE610 This controller has two sets of contacts the Normally Open contact is rated at: 115 Volts 208/240 Volts Full-Load Amps 16 Amps 8 Amps Locked Rotor Amps 96 Amps 48 Amps Ressistive Amps 15 Amps 8 Amps Horsepower 1 hp 1 hp The Normally Closed contact is rated at: 115 Volts 208/240 Volts Full-Load Amps 5.8 Amps 2.9 Amps Locked Rotor Amps 34.8 Amps 17.4 Amps Ressistive Amps 5.8 Amps 2.9 Amps Hoursepower 1/4 hp 1/4 hp
115 Volts 208/240 Volts Full-Load Amps 16 Amps 8 Amps Locked Rotor Amps 96 Amps 48 Amps Ressistive Amps 15 Amps 8 Amps Horsepower 1 hp 1 hp The Normally Closed contact is rated at: 115 Volts 208/240 Volts Full-Load Amps 5.8 Amps 2.9 Amps Locked Rotor Amps 34.8 Amps 17.4 Amps Ressistive Amps 5.8 Amps 2.9 Amps Hoursepower 1/4 hp 1/4 hp